Application Testing A Distributed Systems Model |
The SimoTime Home Page |
This document is a work-in-progress or WIP.
This document will describe and demonstrate how to create an environment for Application Regression Testing on a Windows Platform. The Test Cases used in this scenario were downloaded from a z/OS Mainframe System.
1. | Create/Restore a Test System |
2. | Run the Test Cases |
3. | Review the Results |
4. | Compare two data files |
Note: The references in this document are intended as a guideline or model. It will be necessary to make adjustments for different user environments.
We have made a significant effort to ensure the documents and software technologies are correct and accurate. We reserve the right to make changes without notice at any time. The function delivered in this version is based upon the enhancement requests from a specific group of users. The intent is to provide changes as the need arises and in a timeframe that is dependent upon the availability of resources.
Copyright © 1987-2025
SimoTime Technologies and Services
All Rights Reserved
This section will describe how to do perform a complete application test cycle.
Execute the script (a Windows Command File) that will create the libraries (or directories) and populate the libraries with the application software to be tested and a new copy of the test data.
Explore how to create a new application testing environment using a scripted process that may be executed on a scheduled basis or on demand. This process uses a Windows Command File and runs on a Windows System with Micro Focus Enterprise Developer.
The following flowchart is an overview of the Library (or directory structure) that will be created.
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Note-1: This is the primary root directory, for this example it is set to C:\SIMOSAM1. | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Note-2: This is the Development, Production or Test directory, for this example it is set to TEST. |
The Directory Structure used in the Workshop for Micro Focus Server Enterprise Edition |
WIP3
WIP3
WIP3
WIP3
WIP3
The following Windows command file (RT0001W1.cmd) is used to execute a suite of test jobs
@echo OFF rem * ******************************************************************* rem * RT0001W1.cmd - a Windows Command File * rem * This Job Script is provided by SimoTime Technologies * rem * (C) Copyright 1987-2019 All Rights Reserved * rem * Web Site URL: http://www.simotime.com * rem * e-mail: helpdesk@simotime.com * rem * ******************************************************************* rem * rem * Text - Regression Test rem * Author - SimoTime Technologies rem * Date - January 24, 1996 rem * set CmdName=RT0001W1 call ..\Env1BASE %CmdName% set JobStatus=0000 set RTSERVERNAME=SIMOBATA if "%SYSLOG%" == "" set syslog=c:\SimoLIBR\LOGS\SimoTime.LOG set AOK_Count=0 set NOK_Count=0 rem * call SimoNOTE "*******************************************************%CmdName%" call SimoNOTE "Starting %CmdName% Regression Test Suite call SimoNOTE "Schedule ..............................................UVBR00J1" call ezSCHEDULE %RTSERVERNAME% UVBR00J1 IF %ERRORLEVEL% EQU 0 (set /A AOK_Count=%AOK_Count% + 1) ELSE (set /A NOK_Count=%NOK_Count% + 1) call SimoNOTE "AOKcount Generate Count for AOK is %AOK_Count% " call SimoNOTE "NOKcount Generate Count for NOK is %NOK_Count% " rem * call SimoNOTE "Schedule ..............................................UVDD01J1" call ezSCHEDULE %RTSERVERNAME% UVDD01J1 IF %ERRORLEVEL% EQU 0 (set /A AOK_Count=%AOK_Count% + 1) ELSE (set /A NOK_Count=%NOK_Count% + 1) call SimoNOTE "AOKcount Generate Count for AOK is %AOK_Count% " call SimoNOTE "NOKcount Generate Count for NOK is %NOK_Count% " rem * call SimoNOTE "Schedule ..............................................UVDD01J2" call ezSCHEDULE %RTSERVERNAME% UVDD01J2 IF %ERRORLEVEL% EQU 0 (set /A AOK_Count=%AOK_Count% + 1) ELSE (set /A NOK_Count=%NOK_Count% + 1) call SimoNOTE "AOKcount Generate Count for AOK is %AOK_Count% " call SimoNOTE "NOKcount Generate Count for NOK is %NOK_Count% " rem * call SimoNOTE "Schedule ..............................................CBWAITJ1" call ezSCHEDULE %RTSERVERNAME% CBWAITJ1 IF %ERRORLEVEL% EQU 0 (set /A AOK_Count=%AOK_Count% + 1) ELSE (set /A NOK_Count=%NOK_Count% + 1) call SimoNOTE "AOKcount Generate Count for AOK is %AOK_Count% " call SimoNOTE "NOKcount Generate Count for NOK is %NOK_Count% " rem * call SimoNOTE "Schedule ..............................................CBLJUSJ2" call ezSCHEDULE %RTSERVERNAME% CBLJUSJ2 IF %ERRORLEVEL% EQU 0 (set /A AOK_Count=%AOK_Count% + 1) ELSE (set /A NOK_Count=%NOK_Count% + 1) call SimoNOTE "AOKcount Generate Count for AOK is %AOK_Count% " call SimoNOTE "NOKcount Generate Count for NOK is %NOK_Count% " rem * call SimoNOTE "Schedule ..............................................CBLJUSJ1" call ezSCHEDULE %RTSERVERNAME% CBLJUSJ1 IF %ERRORLEVEL% EQU 0 (set /A AOK_Count=%AOK_Count% + 1) ELSE (set /A NOK_Count=%NOK_Count% + 1) call SimoNOTE "AOKcount Generate Count for AOK is %AOK_Count% " call SimoNOTE "NOKcount Generate Count for NOK is %NOK_Count% " rem * call SimoNOTE "Validate 80/80 Compare of CBLJUSJ1 Job ................VALIDATE" set RS0080D1=%BASECAT%\APPL\SIMOTIME.DATA.JUSTPUT1.DAT set RS0080D2=%BASECAT%\ZERO\SIMOTIME.DATA.JUSTPUT1.DAT call SimoNOTE "OBTAINED is %RS0080D1%" call SimoNOTE "EXPECTED is %RS0080D2%" run CPRS80C1 IF %ERRORLEVEL% EQU 0 (set /A AOK_Count=%AOK_Count% + 1) ELSE (set /A NOK_Count=%NOK_Count% + 1) call SimoNOTE "AOKcount Generate Count for AOK is %AOK_Count% " call SimoNOTE "NOKcount Generate Count for NOK is %NOK_Count% " rem * call SimoNOTE "Schedule ..............................................CBLBITJ1" call ezSCHEDULE %RTSERVERNAME% CBLBITJ1 IF %ERRORLEVEL% EQU 0 (set /A AOK_Count=%AOK_Count% + 1) ELSE (set /A NOK_Count=%NOK_Count% + 1) rem * call SimoNOTE "Schedule ..............................................CBLRAZJ2" call ezSCHEDULE %RTSERVERNAME% CBLRAZJ2 IF %ERRORLEVEL% EQU 0 (set /A AOK_Count=%AOK_Count% + 1) ELSE (set /A NOK_Count=%NOK_Count% + 1) call SimoNOTE "AOKcount Generate Count for AOK is %AOK_Count% " call SimoNOTE "NOKcount Generate Count for NOK is %NOK_Count% " rem * call SimoNOTE "Schedule ..............................................MKZEROJ1" call ezSCHEDULE %RTSERVERNAME% MKZEROJ1 IF %ERRORLEVEL% EQU 0 (set /A AOK_Count=%AOK_Count% + 1) ELSE (set /A NOK_Count=%NOK_Count% + 1) call SimoNOTE "AOKcount Generate Count for AOK is %AOK_Count% " call SimoNOTE "NOKcount Generate Count for NOK is %NOK_Count% " rem * call SimoNOTE "Schedule ..............................................CBLRAZJ1" call ezSCHEDULE %RTSERVERNAME% CBLRAZJ1 IF %ERRORLEVEL% EQU 0 (set /A AOK_Count=%AOK_Count% + 1) ELSE (set /A NOK_Count=%NOK_Count% + 1) call SimoNOTE "AOKcount Generate Count for AOK is %AOK_Count% " call SimoNOTE "NOKcount Generate Count for NOK is %NOK_Count% " rem * call SimoNOTE "Conclude %CmdName% Regression Test Suite call SimoNOTE "AOKcount Generate Count for AOK is %AOK_Count% " call SimoNOTE "NOKcount Generate Count for NOK is %NOK_Count% " if %NOK_Count% == 0 goto EojAok goto EojNok :EojAok call SimoNOTE "Finished %CmdName%, Exit Status is 0" start EZJESLOG exit /B 0 :EojNok call SimoNOTE "ABENDING %CmdName%, Exit Status is 16" start EZJESLOG exit /B 16 :End pause
WIP3
WIP2
WIP2
WIP1
WIP2
WIP2
A Batch Server can be configured in a Micro Focus environment. The will provide the capability of submitting user-coded JCL Members that will be accepted into a job queue and executed by a job initiator.
Explore how to Configure a Batch JES sub-system (or Server Instance) that will run under Micro Focus Enterprise Server and execute batch jobs using JCL.
WIP2
WIP1
The following Windows command file (MDIRTEST.cmd) is used to create a new test environment.
@echo OFF echo ********************************************************************* echo * MDIRTEST.cmd - a Windows Command File * echo * This program is provided by SimoTime Technologies * echo * (C) Copyright 1987-2017 All Rights Reserved * echo * Web Site URL: http://www.simotime.com * echo * e-mail: helpdesk@simotime.com * echo ********************************************************************* rem * rem * This command will create a directory structure for an Application rem * TEST environment. rem * call ..\ENV1BASE set CmdName=MDIRTEST rem * rem ********************************************************************* rem * Step 01 of nn, Job Setup rem * call SimoNOTE "************************************************************%CmdName%.CMD" call SimoNOTE "JOBSETUP Function, JobName %CmdName%.CMD" set Base1st=SIMOSAM1 set Base2nd=TEST set BaseDir=c:\%Base1st%\%Base2nd% if exist %BaseDir% goto :Abend10 set BaseLib1=%BaseDir% echo %BASEDIR% set DefaultServer=SIMTSTS1 rem * rem ********************************************************************* rem * Step 02 of nn, Build a Directory Structure rem * call SimoNOTE "*----------------------------------------------------------*" call SimoNOTE "BLDLDIRS Functions, Build the Directory Structure" md %BaseDir% md %BaseDir%\ADM1 md %BaseDir%\ADM1\CNTL md %BaseDir%\ADM1\DATA md %BaseDir%\ADM1\DATA\UTIL md %BaseDir%\ADM1\DATA\WRK1 md %BaseDir%\DATA md %BaseDir%\DATA\APPL md %BaseDir%\DATA\Asc1 md %BaseDir%\DATA\Ebc1 md %BaseDir%\DATA\FTP1 md %BaseDir%\DATA\SPOOL md %BaseDir%\DATA\TXT1 md %BaseDir%\DATA\Wrk1 md %BaseDir%\DATA\XLSS md %BaseDir%\DATA\ZERO md %BaseDir%\DOCS md %BaseDir%\HOLD md %BaseDir%\HTML md %BaseDir%\IMSLIB md %BaseDir%\JCL md %BaseDir%\JCLINCS md %BaseDir%\LOADLIB md %BaseDir%\LOGS md %BaseDir%\LOGS\%DefaultServer% md %BaseDir%\LOGS\MFJESLOG md %BaseDir%\PARMLIB md %BaseDir%\PROCLIB md %BaseDir%\REXXLIB md %BaseDir%\SYS1 md %BaseDir%\SYS1\CONFIG md %BaseDir%\SYS1\JCL md %BaseDir%\SYS1\LOADLIB md %BaseDir%\SYS1\PARMLIB md %BaseDir%\SYS1\LOGS md %BaseDir%\SYS1\LOGS\%DefaultServer% md %BaseDir%\SYS1\LOGS\MFJESLOG md %BaseDir%\ZIPS rem * rem ********************************************************************* rem * Step 03 of nn, Build Environment for Execution-Time of Test Cases rem * call SimoNOTE "*----------------------------------------------------------*" call SimoNOTE "BLDLENV1 Function, Build Execution-Time Commands" copy C:\SimoWEB1\simologo.jpg %BaseDir%\HTML\simologo.jpg rem * echo set BaseLib1=%BaseDir%>Env1BASEscript002.TXT echo set BaseLib8=c:\SIMOSAM8>>Env1BASEscript002.TXT echo set SimoLIBR=c:\SimoLIBR>>Env1BASEscript002.TXT echo set JESSERVERNAME=%DefaultServer%>>Env1BASEscript002.TXT copy Env1BASEscript001.TXT + Env1BASEscript002.TXT + Env1BASEscript003.TXT %BaseDir%\ENV1BASE.cmd rem * echo call c:\SimoSam1\TEST\ENV1BASE.cmd >%BaseDir%\CMDSETUP.CMD rem * echo 01RCMD00001>%BaseDir%\SYS1\LOGS\%DefaultServer%\CMDTOKEN.CFG echo ES-Server=-r%DefaultServer%>%BaseDir%\SYS1\LOGS\%DefaultServer%\MFBSI.CFG echo JESYSMSG>>%BaseDir%\SYS1\LOGS\%DefaultServer%\MFBSI.CFG echo SJobID=JCL>>%BaseDir%\SYS1\LOGS\%DefaultServer%\MFBSI.CFG echo StartupTimeout=300>>%BaseDir%\SYS1\LOGS\%DefaultServer%\MFBSI.CFG echo RunTimeout=600>>%BaseDir%\SYS1\LOGS\%DefaultServer%\MFBSI.CFG echo AlertBackTimeout=600>>%BaseDir%\SYS1\LOGS\%DefaultServer%\MFBSI.CFG rem * rem ********************************************************************* rem * Step 04 of nn, Build non-relational Data Files rem * call SimoNOTE "*----------------------------------------------------------*" call SimoNOTE "MKAPLSUP Function,Build Data Files used for Application Support" copy c:\SimoSam8\SYS1\XLSS\TEST\*.XLSX %BaseDir%\DATA\XLSS\*.XLSX copy c:\SimoSam8\SYS1\XLSS\TEST\*.CSV %BaseDir%\DATA\XLSS\*.CSV rem * copy c:\SimoSam8\DATALIBR\*.DAT %BaseDir%\DATA\APPL\*.DAT rem * set GETLIBR=c:\SimoSam1\DEVL\ADM1\DATA\UTIL copy %GETLIBR%\SIMOTIME.UTIL.APMASTER.* %BaseDir%\ADM1\DATA\UTIL\SIMOTIME.UTIL.APMASTER.* copy %GETLIBR%\SIMOTIME.UTIL.FPMASTER.* %BaseDir%\ADM1\DATA\UTIL\SIMOTIME.UTIL.FPMASTER.* rem * copy c:\%BASE1ST%\DEVL\DATA\ZERO\SIMOTIME.DATA.JUSTPUT1.DAT %BASEDIR%\DATA\ZERO\SIMOTIME.DATA.JUSTPUT1.DAT rem * rem ********************************************************************* rem * Step 05 of nn, Promote Executables, Load Members, Screens, ParmLibs rem * copy c:\SimoSam1\DEVL\JCL\*.JCL %BaseDir%\JCL\*.JCL copy c:\SimoSam1\DEVL\JCLINCS\*.INC %BaseDir%\JCLINCS\*.INC copy c:\SimoSam1\DEVL\PROCLIB\*.PRC %BaseDir%\PROCLIB\*.PRC copy c:\SimoSam1\DEVL\PARMLIB\*.CTL %BaseDir%\PARMLIB\*.CTL copy c:\SimoSam1\DEVL\LOADLIB\*.GNT %BaseDir%\LOADLIB\*.GNT copy c:\SimoSam1\DEVL\LOADLIB\*.MOD %BaseDir%\LOADLIB\*.MOD copy c:\SimoSam1\DEVL\LOADLIB\*.CMD %BaseDir%\LOADLIB\*.CMD copy C:\%Base1st%\DEVL\ADM1\DATA\TXT1\RT0001W1FORTEST.txt %BaseDir%\LOADLIB\RT0001W1.cmd rem * copy c:\SimoSam1\DEVL\PARMLIB\CUQCP1T1.CTL %BaseDir%\PARMLIB\CUQCP1X1.CTL rem * rem ********************************************************************* rem * Step 06 of nn, Promote Members for System Support Functions rem * call SimoNOTE "*----------------------------------------------------------*" call SimoNOTE "MKSYSSUP Function, Build Members used for System Support" copy c:\SimoSam1\DEVL\SYS1\CONFIG\CATMAPA1.CFG %BaseDir%\SYS1\CONFIG\CATMAPA1.CFG copy c:\SimoSam1\DEVL\SYS1\CONFIG\EXTFHBIG.CFG %BaseDir%\SYS1\CONFIG\EXTFHBIG.CFG copy c:\SimoSam1\DEVL\SYS1\CONFIG\DFHDRDAT.* %BaseDir%\SYS1\CONFIG\DFHDRDAT.* copy c:\SimoSam1\DEVL\SYS1\LOADLIB\SYS1*.CMD %BaseDir%\SYS1\LOADLIB\SYS1*.CMD copy c:\SimoSam1\DEVL\SYS1\LOADLIB\MFBSI*.GNT %BaseDir%\SYS1\LOADLIB\MFBSI*.GNT copy c:\SimoSam1\DEVL\SYS1\LOADLIB\MFBSI*.INT %BaseDir%\SYS1\LOADLIB\MFBSI*.INT copy c:\SimoSam1\DEVL\SYS1\LOADLIB\ESODBCXA.DLL %BaseDir%\SYS1\LOADLIB\ESODBCXA.DLL copy c:\SimoSam1\DEVL\SYS1\JCL\*.JCL %BaseDir%\SYS1\JCL\*.JCL copy c:\SimoSam1\DEVL\SYS1\LOADLIB\CAT*.CMD %BaseDir%\SYS1\LOADLIB\CAT*.CMD echo set JESSERVERNAME=SIMTSTS1>>%BaseDir%\SYS1\LOADLIB\CATALLE1.CMD echo call CATALLE2>>%BaseDir%\SYS1\LOADLIB\CATALLE1.CMD rem * copy c:\SimoSam1\DEVL\ADM1\DATA\MKTLIBJ1FORTEST.txt %BaseDir%\SYS1\JCL\MKTLIBJ1.jcl rem * rem ********************************************************************* rem * Step 07 of nn, Promote Installation Verification Programs rem * call SimoNOTE "*----------------------------------------------------------*" call SimoNOTE MKPDSJCL Function, Build Members used for Installation Verification" rem copy c:\SimoSam1\DEVL\JCL\UVBR00J1.JCL %BaseDir%\JCL\UVBR00J1.JCL rem copy c:\SimoSam1\DEVL\JCL\UVDD01J1.JCL %BaseDir%\JCL\UVDD01J1.JCL rem copy c:\SimoSam1\DEVL\JCL\UVDD01J2.JCL %BaseDir%\JCL\UVDD01J2.JCL rem copy c:\SimoSam1\DEVL\PARMLIB\UVDD01T1.CTL %BaseDir%\PARMLIB\UVDD01T1.CTL rem * call SimoNOTE "*----------------------------------------------------------*" call SimoNOTE "Continue TASK_005, Build JCL to Create PDS Catalog Entries" call SIMONOTE "DataTake is %Base1st%\DEVL\ADM1\DATA\TXT1\MKTLIBJ1FORTEST.txt" call SIMONOTE "DataMake is %BASEDIR%\SYS1\JCL\MKTLIBJ1.jcl copy C:\%Base1st%\DEVL\ADM1\DATA\TXT1\MKTLIBJ1FORTEST.txt %BASEDIR%\SYS1\JCL\MKTLIBJ1.jcl rem * goto :EOJAOK :Abend10 call SimoNOTE "*----------------------------------------------------------*" call SimoNOTE "ABENDING The Directory Already Exists... %BaseDir%" call SimoNOTE "ABENDING JobName %CmdName%.CMD" goto :End :EOJAOK call SimoNOTE "*----------------------------------------------------------*" call SimoNOTE "Finished JobName %CmdName%.CMD" :End pause
WIP2
This document will describe and demonstrate how to create an environment for Application Regression Testing on a Windows Platform. This document may be used as a tutorial for new programmers or as a quick reference for experienced programmers.
In the world of programming there are many ways to solve a problem. This documentation and software were developed and tested on systems that are configured for a SIMOTIME environment based on the hardware, operating systems, user requirements and security requirements. Therefore, adjustments may be needed to execute the jobs and programs when transferred to a system of a different architecture or configuration.
SIMOTIME Services has experience in moving or sharing data or application processing across a variety of systems. For additional information about SIMOTIME Services or Technologies please contact us using the information in the Contact or Feedback section of this document.
Software Agreement and Disclaimer
Permission to use, copy, modify and distribute this software, documentation or training material for any purpose requires a fee to be paid to SimoTime Technologies. Once the fee is received by SimoTime the latest version of the software, documentation or training material will be delivered and a license will be granted for use within an enterprise, provided the SimoTime copyright notice appear on all copies of the software. The SimoTime name or Logo may not be used in any advertising or publicity pertaining to the use of the software without the written permission of SimoTime Technologies.
SimoTime Technologies makes no warranty or representations about the suitability of the software, documentation or learning material for any purpose. It is provided "AS IS" without any expressed or implied warranty, including the implied warranties of merchantability, fitness for a particular purpose and non-infringement. SimoTime Technologies shall not be liable for any direct, indirect, special or consequential damages resulting from the loss of use, data or projects, whether in an action of contract or tort, arising out of or in connection with the use or performance of this software, documentation or training material.
This section includes links to documents with additional information that are beyond the scope and purpose of this document. The first group of documents may be available from a local system or via an internet connection, the second group of documents will require an internet connection.
Note: A SimoTime License is required for the items to be made available on a local system or server.
The following links may be to the current server or to the Internet.
Note: The latest versions of the SimoTime Documents and Program Suites are available on the Internet and may be accessed using the icon. If a user has a SimoTime Enterprise License the Documents and Program Suites may be available on a local server and accessed using the icon.
Explore An Enterprise System Model that describes and demonstrates how Applications that were running on a Mainframe System and non-relational data that was located on the Mainframe System were copied and deployed in a Microsoft Windows environment with Micro Focus Enterprise Server.
Explore the COBOL Connection for more examples of COBOL programming techniques and sample code.
Explore an Extended List of Software Technologies that are available for review and evaluation. The software technologies (or Z-Packs) provide individual programming examples, documentation and test data files in a single package. The Z-Packs are usually in zip format to reduce the amount of time to download.
Explore The ASCII and EBCDIC Translation Tables. These tables are provided for individuals that need to better understand the bit structures and differences of the encoding formats.
Explore The File Status Return Codes that are used to interpret the results of accessing VSAM data sets and/or QSAM files.
The following links will require an internet connection.
A good place to start is The SimoTime Home Page for access to white papers, program examples and product information. This link requires an Internet Connection
Explore The Micro Focus Web Site for more information about products (including Micro Focus COBOL) and services available from Micro Focus. This link requires an Internet Connection.
Explore the Glossary of Terms for a list of terms and definitions used in this suite of documents and white papers.
This document was created and is maintained by SimoTime Technologies. If you have any questions, suggestions, comments or feedback please use the following contact information.
1. | Send an e-mail to our helpdesk. |
1.1. | helpdesk@simotime.com. |
2. | Our telephone numbers are as follows. |
2.1. | 1 415 763-9430 office-helpdesk |
2.2. | 1 415 827-7045 mobile |
We appreciate hearing from you.
SimoTime Technologies was founded in 1987 and is a privately owned company. We specialize in the creation and deployment of business applications using new or existing technologies and services. We have a team of individuals that understand the broad range of technologies being used in today's environments. Our customers include small businesses using Internet technologies to corporations using very large mainframe systems.
Quite often, to reach larger markets or provide a higher level of service to existing customers it requires the newer Internet technologies to work in a complementary manner with existing corporate mainframe systems. We specialize in preparing applications and the associated data that are currently residing on a single platform to be distributed across a variety of platforms.
Preparing the application programs will require the transfer of source members that will be compiled and deployed on the target platform. The data will need to be transferred between the systems and may need to be converted and validated at various stages within the process. SimoTime has the technology, services and experience to assist in the application and data management tasks involved with doing business in a multi-system environment.
Whether you want to use the Internet to expand into new market segments or as a delivery vehicle for existing business functions simply give us a call or check the web site at http://www.simotime.com
Return-to-Top |
Quality Assurance Testing, a Distributed Model |
Copyright © 1987-2025 SimoTime Technologies and Services All Rights Reserved |
When technology complements business |
http://www.simotime.com |