TCNPEKW2.cmd Job Script for a Windows System |
The SimoTime Home Page |
This document shows the content of a user-defined job script that is used for batch processing.
We have made a significant effort to ensure the documents and software technologies are correct and accurate. We reserve the right to make changes without notice at any time. The function delivered in this version is based upon the enhancement requests from a specific group of users. The intent is to provide changes as the need arises and in a timeframe that is dependent upon the availability of resources.
Copyright © 1987-2023
SimoTime Technologies and Services
All Rights Reserved
This is the job script that will prepare the environment and execute the program that will process a file containing text strings that use EBCDIC or ASCII encoding and numeric values that may be stored in a Binary, Packed-Decimal or Zoned-Decimal format.
@echo OFF set JOB_NAME=TCNPEKW2 rem * ******************************************************************* rem * Batch Job Script - a Windows Command File * rem * Provided by SimoTime Technologies and Services * rem * (C) Copyright 1987-2023 All Rights Reserved * rem * Web Site URL: http://www.simotime.com * rem * e-mail: helpdesk@simotime.com * rem * ******************************************************************* rem * rem * Text - Field Peek Sequential File with Multiple Numeric Formats rem * Author - SimoTime Technologies and Services rem * Date - January 24, 1996 rem * rem * This Job Script will run on a Windows System. rem * rem * This job will execute a program that does the following. rem * rem * 1. Sequentially access an input file (SYSUT1, a RSEQ). rem * rem * 2. The records that are read from SYSUT1 are selected for rem * processing by the specifications from a control file (SYSUT3) rem * that define a range of records to be processed. rem * rem * 3. The Text Strings and Hexadecimal dump information will be rem * written to the SYSOUT Device. rem * rem * For more information or questions please contact SimoTime rem * Technologies. The version control number is 20.00.00 rem * rem * Our e-mail address is: helpdesk@simotime.com rem * Also, visit our Web Site at http://www.simotime.com rem * ******************************************************************* rem * rem * ************ rem * * TCNPEKW2 * rem * ********cmd* rem * * rem * * rem * ************ ************ ************ rem * * instream *-----* echo *-----* SYSUT3 * rem * *******data* ********cmd* *******lseq* rem * * rem * * rem * ************ ************ ************ rem * * SYSUT1 *--*--* TCNPEKC1 *--*----------------*--* SYSOUT * rem * *******rseq* * ********cbl* * * *******lseq* rem * * * * * rem * * * * ********** * rem * * * *---* call * * rem * * * ********** * rem * * * * * rem * ************ * * ************ * rem * * SYSUT3 *--* * * TCMPEKR1 *--* rem * *******lseq* * ********cbl* rem * * * rem * * ************ rem * * * STPEEKC1 * rem * * ********cbl* rem * * rem * ************ rem * * EOJ * rem * ************ rem * rem * ******************************************************************* rem * if "%ENV1BASE_CALL%" == "OFF" goto SKIP_CALL call ..\ENV1BASE %JOB_NAME% :SKIP_CALL set JOB_STATUS=0 if "%SYSLOG%" == "" set syslog=c:\SimoLIBR\LOGS\SimoTime.LOG rem * call SIMONOTE "*-----------------------------------------------------------------------------*01 of 04" call SIMONOTE "* Job_Step 01 of 04, Preparing the System and job environments rem * set SYSUT1=%BaseLib1%\DATA\ASC1\TCNBRSD2.DAT set SYSUT3=%BaseLib1%\PARMLIB\USERANGE.txt set SYSOUT=%BaseLib1%\LOGS\SYSOUT_%JOB_NAME%.txt call SIMONOTE "* SYSUT1 is %SYSUT1% " call SIMONOTE "* SYSUT3 is %SYSUT3% " call SIMONOTE "* SYSOUT is %SYSOUT% " if exist %SYSOUT% erase %SYSOUT% rem * call SIMONOTE "*-----------------------------------------------------------------------------*02 of 04" call SIMONOTE "* Job_Step 02 of 04, Create a Control File for Record Selection" echo /RANGE 1 2 >%SYSUT3% rem * call SIMONOTE "*-----------------------------------------------------------------------------*03 of 04" call SIMONOTE "* Job_Step 03 of 04, Execute the Field Peek Program" run TCNPEKC1 if not "%ERRORLEVEL%" == "0" set JOB_STATUS=10 rem * :EOJTAG call SIMONOTE "*-----------------------------------------------------------------------------*04 of 04" call SIMONOTE "* Job_Step 04 of 04, End of Job processing" if not %JOB_STATUS% == 0 goto :EojNok :EojAok call SIMONOTE "* Finished JobName %JOB_NAME%, Job Status is %JOB_STATUS% " goto :EOJEND :EojNok call SIMONOTE "* ABENDING JobName %JOB_NAME%, Job Status is %JOB_STATUS% " :EOJEND if not "SIMOGENS" == "BATCH" start notepad %SYSOUT% if not "SIMOGENS" == "BATCH" call SIMONOTE "* The Field Display information should be shown in a separate window " :End call SIMONOTE "* Log_Info JOBLOG is %SIMONOTE% " call SIMONOTE "* Log_Info SYSOUT is %SYSOUT% " if not "%SIMOGENS%" == "BATCH" pause exit /b %JOB_STATUS%
This document shows the content of a user-defined job script that is used for batch processing. This document may be used to assist as a tutorial for new programmers or as a quick reference for experienced programmers.
In the world of programming there are many ways to solve a problem. This documentation and software were developed and tested on systems that are configured for a SIMOTIME environment based on the hardware, operating systems, user requirements and security requirements. Therefore, adjustments may be needed to execute the jobs and programs when transferred to a system of a different architecture or configuration.
SIMOTIME Services has experience in moving or sharing data or application processing across a variety of systems. For additional information about SIMOTIME Services or Technologies please contact us using the information in the Contact, Comment or Feedback section of this document.
Software Agreement and Disclaimer
Permission to use, copy, modify and distribute this software, documentation or training material for any purpose requires a fee to be paid to SimoTime Technologies. Once the fee is received by SimoTime the latest version of the software, documentation or training material will be delivered and a license will be granted for use within an enterprise, provided the SimoTime copyright notice appear on all copies of the software. The SimoTime name or Logo may not be used in any advertising or publicity pertaining to the use of the software without the written permission of SimoTime Technologies.
SimoTime Technologies makes no warranty or representations about the suitability of the software, documentation or learning material for any purpose. It is provided "AS IS" without any expressed or implied warranty, including the implied warranties of merchantability, fitness for a particular purpose and non-infringement. SimoTime Technologies shall not be liable for any direct, indirect, special or consequential damages resulting from the loss of use, data or projects, whether in an action of contract or tort, arising out of or in connection with the use or performance of this software, documentation or training material.
This section includes links to documents with additional information that are beyond the scope and purpose of this document. The first group of documents may be available from a local system or via an Internet connection, the second group of documents will require an Internet connection.
Note: A SIMOTIME License is required for the items to be made available on a local system or server.
The following links may be to the current server or to the Internet.
Note: The latest versions of the SimoTime Documents and Program Suites are available on the Internet and may be accessed using the icon. If a user has a SimoTime Enterprise License the Documents and Program Suites may be available on a local server and accessed using the icon.
Explore An Enterprise System Model that describes and demonstrates how Applications that were running on a Mainframe System and non-relational data that was located on the Mainframe System were copied and deployed in a Microsoft Windows environment with Micro Focus Enterprise Server.
Explore The Binary or COMP format for numeric data strings. This numeric structure is supported by COBOL and may be explicitly defined with the "USAGE IS COMP" or "USAGE IS BINARY" clause.
Explore The Packed-Decimal or COMP-3 format for numeric data strings. This numeric structure is supported by COBOL and may be explicitly defined with the "USAGE IS COMP-3" clause.
Explore The Zoned-Decimal format for numeric data strings. This numeric structure is the default numeric for COBOL and may be explicitly defined with the "USAGE IS DISPLAY" clause.
Explore How to Generate a Data File Convert Program using simple specification statements in a Process Control File (PCF). This link to the User Guide includes the information necessary to create a Process Control File and generate the COBOL programs that will do the actual data file conversion. The User Guide contains a list of the PCF statements that are used for the data file convert process.
Explore How to Generate a Data File Compare, Validate or Hex-Dump Program using simple specification statements in a Process Control File (PCF). This link to the User Guide includes the information necessary to create a Process Control File and generate the COBOL programs that will do a data file compare, accumulate summary totals with a record count or produce a Hex-Dump of records in a VSAM, KSDS based on a list of user-defined keys. The User Guide contains a list of the PCF statements that are used for the data file compare, validate or dump process.
Explore the COBOL Connection for more examples of COBOL programming techniques and sample code.
Explore The ASCII and EBCDIC Translation Tables. These tables are provided for individuals that need to better understand the bit structures and differences of the encoding formats.
Explore The File Status Return Codes to interpret the results of accessing VSAM data sets and/or QSAM files.
The following links will require an Internet connection.
A good place to start is The SimoTime Home Page for access to white papers, program examples and product information. This link requires an Internet Connection
Explore The Micro Focus Web Site for more information about products (including Micro Focus COBOL) and services available from Micro Focus. This link requires an Internet Connection.
Explore the GnuCOBOL Technologies available from SourceForge. SourceForge is an Open Source community resource dedicated to helping open source projects be as successful as possible. GnuCOBOL (formerly OpenCOBOL) is a COBOL compiler with run time support. The compiler (cobc) translates COBOL source to executable using intermediate C, designated C compiler and linker. This link will require an Internet Connection.
Explore the Glossary of Terms for a list of terms and definitions used in this suite of documents and white papers.
This document was created and is maintained by SimoTime Technologies and Services. If you have any questions, suggestions, comments or feedback please use the following contact information.
1. | Send an e-mail to our helpdesk. |
1.1. | helpdesk@simotime.com. |
2. | Our telephone numbers are as follows. |
2.1. | 1 415 763-9430 office-helpdesk |
2.2. | 1 415 827-7045 mobile |
We appreciate hearing from you.
SimoTime Technologies was founded in 1987 and is a privately owned company. We specialize in the creation and deployment of business applications using new or existing technologies and services. We have a team of individuals that understand the broad range of technologies being used in today's environments. Our customers include small businesses using Internet technologies to corporations using very large mainframe systems.
Quite often, to reach larger markets or provide a higher level of service to existing customers it requires the newer Internet technologies to work in a complementary manner with existing corporate mainframe systems. We specialize in preparing applications and the associated data that are currently residing on a single platform to be distributed across a variety of platforms.
Preparing the application programs will require the transfer of source members that will be compiled and deployed on the target platform. The data will need to be transferred between the systems and may need to be converted and validated at various stages within the process. SimoTime has the technology, services and experience to assist in the application and data management tasks involved with doing business in a multi-system environment.
Whether you want to use the Internet to expand into new market segments or as a delivery vehicle for existing business functions simply give us a call or check the web site at http://www.simotime.com
Return-to-Top |
TCNPEKW2.cmd - Job Script |
Copyright © 1987-2023 SimoTime Technologies and Services All Rights Reserved |
When technology complements business |
http://www.simotime.com |