TCKPKAW1.cmd
Job Script for a Windows System
  Table of Contents  v-23.01.01 
  Introduction
  Batch Job Script
  Summary
  Software Agreement and Disclaimer
  Downloads and Links
  Current Server or Internet Access
  Internet Access Required
  Glossary of Terms
  Contact, Comments or Feedback
  Company Overview
The SimoTime Home Page 

Table of Contents Previous Section Next Section Introduction

This document shows the content of an ASCII/Text file. The record structure may use one of the following formats.

1. Comma-Separated-Values (CSV) format.
2. A group of concatenated Text string of fixed length. The numeric values may be padded with leading zeroes and the text values may be padded with trailing spaces.
3. A single string of ASCII-encoded text.

 


We have made a significant effort to ensure the documents and software technologies are correct and accurate. We reserve the right to make changes without notice at any time. The function delivered in this version is based upon the enhancement requests from a specific group of users. The intent is to provide changes as the need arises and in a timeframe that is dependent upon the availability of resources.

Copyright © 1987-2023
SimoTime Technologies and Services
All Rights Reserved

Table of Contents Previous Section Next Section Batch Job Script

The following shows the content of a user-defined, ASCII/Text file.

The TCKPKAW1 job script will present the fields within a record structure in a hexadecimal notation format. The hexadecimal notation may be displayed or written to an ASCII/Text logging file.

The following is an example of the hexadecimal dump information provided for an ASCII encoded data string that contains "ABCDEFGHIJKLMNOPQRSTUVWXYZ".

Each single byte in the preceding string will produce two bytes of hexadecimal notation. The Hex Notation may be presented in 1 of 2 formats.

Format 1 will present a single line of Hex Notation.

Hex Notation: 4142434445464748494A4B4C4D4E4F505152535455565758595A

Format 2 will present two lines of Hex Notation. The first line shows the content of bits 0-3 for each byte of data. The second line shows the content of bits 4-7 for each byte of data.

1st Nibble is 44444444444444455555555555
2nd Nibble is 123456789ABCDEF0123456789A

Note: Bits 0-3 may be referred to as the 1st nibble of a byte of data. Bits 4-7 may be referred to as the 2nd nibble of a byte of data.

@echo OFF
     set JOB_NAME=TCKPKAW1
rem  * *******************************************************************
rem  *             Batch Job Script - a Windows Command File             *
rem  *          Provided by SimoTime Technologies and Services           *
rem  *           (C) Copyright 1987-2023 All Rights Reserved             *
rem  *             Web Site URL:   http://www.simotime.com               *
rem  *                   e-mail:   helpdesk@simotime.com                 *
rem  * *******************************************************************
rem  *
rem  * Text   - Field Peek Sequential File of Numeric Strings to Hex-Dump
rem  * Author - SimoTime Technologies and Services
rem  * Date   - January 24, 1996
rem  *
rem  * This Job Script will run on a Windows System. The following
rem  * describes each of the steps within this job.
rem  *
rem  *   1. Prepare the System and Job Environments.
rem  *   2. Create a Control File that will define a range of relative
rem  *      record numbers to be use to select records for processing.
rem  *   3. Execute a program that will read an ASCII encoded,
rem  *      Record Sequential (RSEQ) file that contains various numeric
rem  *      values stored in a Binary, Packed-Deciml (COMP-3) or Zoned-
rem  *      Decimal format. The records that are read from SYSUT1 are
rem  *      selected for processing by the specifications from a control
rem  *      file (SYSUT3) that define a range of records to be processed.
rem  *      The Text Strings and Hexadecimal dump information will be
rem  *      written to the SYSOUT Device.
rem  *   4. End of Job processing.
rem  *
rem  * For more information or questions please contact SimoTime
rem  * Technologies. The version control number is 22.01.01
rem  *
rem  * Our e-mail address is: helpdesk@simotime.com
rem  * Also, visit our Web Site at http://www.simotime.com
rem  * *******************************************************************
rem  *
rem  *                    ************
rem  *                    * TCKPKAW1 *
rem  *                    ********cmd*
rem  *                         *
rem  *                         *
rem  *   ************     ************     ************
rem  *   * instream *-----*   echo   *-----*  SYSUT3  *
rem  *   *******data*     ********cmd*     *******lseq*
rem  *                         *
rem  *                         *
rem  *   ************     ************                      ************
rem  *   *  SYSUT1  *--*--* TCKPEKC1 *--*----------------*--*  SYSOUT  *
rem  *   *******rseq*  *  ********cbl*  *                *  *******lseq*
rem  *                 *       *        *                *
rem  *                 *       *        *   **********   *
rem  *                 *       *        *---*  call  *   *
rem  *                 *       *            **********   *
rem  *                 *       *                *        *
rem  *   ************  *       *           ************  *
rem  *   *  SYSUT3  *--*       *           * TCKPEKR1 *--*
rem  *   *******lseq*          *           ********cbl*
rem  *                         *                *
rem  *                         *           ************
rem  *                         *           * STPEEKC1 *
rem  *                         *           ********cbl*
rem  *                         *
rem  *                    ************
rem  *                    *   EOJ    *
rem  *                    ************
rem  *
rem  * *******************************************************************
rem  *
     if "%ENV1BASE_CALL%" == "OFF" goto SKIP_CALL
        call ..\ENV1BASE %JOB_NAME%
:SKIP_CALL
     set JobStatus=0
     if "%SYSLOG%" == "" set syslog=c:\SimoLIBR\LOGS\SimoTime.LOG
rem  *
     call SimoNOTE "*-----------------------------------------------------------------------------*01 of 04"
     call SimoNOTE "* Job_Step 01 of 04, Preparing the System and job environments
rem  *
     set SYSUT1=%BaseLib1%\DATA\ASC1\TCKRSAD1.DAT
     set SYSUT3=%BaseLib1%\PARMLIB\USERANGE.txt
     set SYSOUT=%BaseLib1%\LOGS\SYSOUT_%JOB_NAME%.txt
     call SimoNOTE "* SYSUT1 is %SYSUT1% "
     call SimoNOTE "* SYSUT3 is %SYSUT3% "
     call SimoNOTE "* SYSOUT is %SYSOUT% "
     if exist %SYSOUT% erase %SYSOUT%
rem  *
     call SimoNOTE "*-----------------------------------------------------------------------------*02 of 04"
     call SimoNOTE "* Job_Step 02 of 04, Create a Control File for Record Selection"
     echo /RANGE     1 3 >%SYSUT3%
rem  *
     call SimoNOTE "*-----------------------------------------------------------------------------*03 of 04"
     call SimoNOTE "* Job_Step 03 of 04, Execute the Field Peek Program"
     run TCKPEKC1
     if not "%ERRORLEVEL%" == "0" set JobStatus=10
rem  *
:EOJTAG
     call SimoNOTE "*-----------------------------------------------------------------------------*04 of 04"
     call SimoNOTE "* Job_Step 04 of 04, End of Job processing"
     if not %JobStatus% == 0 goto :EojNok
:EojAok
     call SimoNOTE "* Finished JobName %JOB_NAME%, Job Status is %JobStatus% "
     goto :EOJEND
:EojNok
     call SimoNOTE "* ABENDING JobName %JOB_NAME%, Job Status is %JobStatus% "
:EOJEND
     if not "SIMOGENS" == "BATCH" start notepad %SYSOUT%
     if not "SIMOGENS" == "BATCH" call SIMONOTE "* The Field Display information should be shown in a separate window "
:End
     call SimoNOTE "* Log_Info JOBLOG is %SIMONOTE% "
     call SimoNOTE "* Log_Info SYSOUT is %SYSOUT% "
     if not "%SIMOGENS%" == "BATCH" pause
     exit /B %JobStatus%

Table of Contents Previous Section Next Section Summary

This document shows the content of an ASCII/Text file that has a record structure that uses a Comma-Separated-Values (CSV) format. This document may be used to assist as a tutorial for new programmers or as a quick reference for experienced programmers.

In the world of programming there are many ways to solve a problem. This documentation and software were developed and tested on systems that are configured for a SIMOTIME environment based on the hardware, operating systems, user requirements and security requirements. Therefore, adjustments may be needed to execute the jobs and programs when transferred to a system of a different architecture or configuration.

SIMOTIME Services has experience in moving or sharing data or application processing across a variety of systems. For additional information about SIMOTIME Services or Technologies please contact us using the information in the  Contact, Comment or Feedback  section of this document.

Table of Contents Previous Section Next Section Software Agreement and Disclaimer

Permission to use, copy, modify and distribute this software, documentation or training material for any purpose requires a fee to be paid to SimoTime Technologies. Once the fee is received by SimoTime the latest version of the software, documentation or training material will be delivered and a license will be granted for use within an enterprise, provided the SimoTime copyright notice appear on all copies of the software. The SimoTime name or Logo may not be used in any advertising or publicity pertaining to the use of the software without the written permission of SimoTime Technologies.

SimoTime Technologies makes no warranty or representations about the suitability of the software, documentation or learning material for any purpose. It is provided "AS IS" without any expressed or implied warranty, including the implied warranties of merchantability, fitness for a particular purpose and non-infringement. SimoTime Technologies shall not be liable for any direct, indirect, special or consequential damages resulting from the loss of use, data or projects, whether in an action of contract or tort, arising out of or in connection with the use or performance of this software, documentation or training material.

Table of Contents Previous Section Next Section Downloads and Links

This section includes links to documents with additional information that are beyond the scope and purpose of this document. The first group of documents may be available from a local system or via an Internet connection, the second group of documents will require an Internet connection.

Note: A SIMOTIME License is required for the items to be made available on a local system or server.

Table of Contents Previous Section Next Section Current Server or Internet Access

The following links may be to the current server or to the Internet.

Note: The latest versions of the SimoTime Documents and Program Suites are available on the Internet and may be accessed using the Link to Internet icon. If a user has a SimoTime Enterprise License the Documents and Program Suites may be available on a local server and accessed using the Link to Server icon.

Link to Internet   Link to Server   Explore An Enterprise System Model that describes and demonstrates how Applications that were running on a Mainframe System and non-relational data that was located on the Mainframe System were copied and deployed in a Microsoft Windows environment with Micro Focus Enterprise Server.

Link to Internet   Link to Server   Explore The Binary or COMP format for numeric data strings. This numeric structure is supported by COBOL and may be explicitly defined with the "USAGE IS COMP" or "USAGE IS BINARY" clause.

Link to Internet   Link to Server   Explore The Packed-Decimal or COMP-3 format for numeric data strings. This numeric structure is supported by COBOL and may be explicitly defined with the "USAGE IS COMP-3" clause.

Link to Internet   Link to Server   Explore The Zoned-Decimal format for numeric data strings. This numeric structure is the default numeric for COBOL and may be explicitly defined with the "USAGE IS DISPLAY" clause.

Link to Internet   Link to Server   Explore How to Generate a Data File Convert Program using simple specification statements in a Process Control File (PCF). This link to the User Guide includes the information necessary to create a Process Control File and generate the COBOL programs that will do the actual data file conversion. The User Guide contains a list of the PCF statements that are used for the data file convert process.

Link to Internet   Link to Server   Explore How to Generate a Data File Compare, Validate or Hex-Dump Program using simple specification statements in a Process Control File (PCF). This link to the User Guide includes the information necessary to create a Process Control File and generate the COBOL programs that will do a data file compare, accumulate summary totals with a record count or produce a Hex-Dump of records in a VSAM, KSDS based on a list of user-defined keys. The User Guide contains a list of the PCF statements that are used for the data file compare, validate or dump process.

Link to Internet   Link to Server   Explore the COBOL Connection for more examples of COBOL programming techniques and sample code.

Link to Internet   Link to Server   Explore The ASCII and EBCDIC Translation Tables. These tables are provided for individuals that need to better understand the bit structures and differences of the encoding formats.

Link to Internet   Link to Server   Explore The File Status Return Codes to interpret the results of accessing VSAM data sets and/or QSAM files.

Table of Contents Previous Section Next Section Internet Access Required

The following links will require an Internet connection.

A good place to start is The SimoTime Home Page for access to white papers, program examples and product information. This link requires an Internet Connection

Explore The Micro Focus Web Site for more information about products (including Micro Focus COBOL) and services available from Micro Focus. This link requires an Internet Connection.

Explore the GnuCOBOL Technologies available from SourceForge. SourceForge is an Open Source community resource dedicated to helping open source projects be as successful as possible. GnuCOBOL (formerly OpenCOBOL) is a COBOL compiler with run time support. The compiler (cobc) translates COBOL source to executable using intermediate C, designated C compiler and linker. This link will require an Internet Connection.

Table of Contents Previous Section Next Section Glossary of Terms

Link to Internet   Link to Server   Explore the Glossary of Terms for a list of terms and definitions used in this suite of documents and white papers.

Table of Contents Previous Section Next Section Contact, Comments or Feedback

This document was created and is maintained by SimoTime Technologies and Services. If you have any questions, suggestions, comments or feedback please use the following contact information.

1. Send an e-mail to our helpdesk.
1.1. helpdesk@simotime.com.
2. Our telephone numbers are as follows.
2.1. 1 415 763-9430 office-helpdesk
2.2. 1 415 827-7045 mobile

 

We appreciate hearing from you.

Table of Contents Previous Section Next Section Company Overview

SimoTime Technologies was founded in 1987 and is a privately owned company. We specialize in the creation and deployment of business applications using new or existing technologies and services. We have a team of individuals that understand the broad range of technologies being used in today's environments. Our customers include small businesses using Internet technologies to corporations using very large mainframe systems.

Quite often, to reach larger markets or provide a higher level of service to existing customers it requires the newer Internet technologies to work in a complementary manner with existing corporate mainframe systems. We specialize in preparing applications and the associated data that are currently residing on a single platform to be distributed across a variety of platforms.

Preparing the application programs will require the transfer of source members that will be compiled and deployed on the target platform. The data will need to be transferred between the systems and may need to be converted and validated at various stages within the process. SimoTime has the technology, services and experience to assist in the application and data management tasks involved with doing business in a multi-system environment.

Whether you want to use the Internet to expand into new market segments or as a delivery vehicle for existing business functions simply give us a call or check the web site at http://www.simotime.com


Return-to-Top
TCKPKAW1.cmd - Job Script
Copyright © 1987-2023
SimoTime Technologies and Services
All Rights Reserved
When technology complements business
http://www.simotime.com