TCKPEKC1.cbl Convert, Compare or Review |
The SimoTime Home Page |
This document shows the content of a COBOL Source Member.
We have made a significant effort to ensure the documents and software technologies are correct and accurate. We reserve the right to make changes without notice at any time. The function delivered in this version is based upon the enhancement requests from a specific group of users. The intent is to provide changes as the need arises and in a timeframe that is dependent upon the availability of resources.
Copyright © 1987-2023
SimoTime Technologies and Services
All Rights Reserved
The following is a COBOL Source Member that will process a file containing text strings that use EBCDIC or ASCII encoding and numeric values that may be stored in a Binary, Packed-Decimal or Zoned-Decimal format.
IDENTIFICATION DIVISION. PROGRAM-ID. TCKPEKC1. AUTHOR. SIMOTIME TECHNOLOGIES. ***************************************************************** * This program was generated by SimoZAPS * * A product of SimoTime Technologies * * Our e-mail address is: helpdesk@simotime.com * * Also, visit our Web Site at http://www.simotime.com * * * * Generation Date: 2023-03-03 Generation Time: 21:06:07:29 * * * * Record Record Key * * Function Name Organization Format Max-Min Pos-Len * * PRIMARY SYSUT1 SEQUENTIAL FIXED 00512 * * * * INPUT SYSUT3 ASCII/CRLF FIXED 00512 * ***************************************************************** ENVIRONMENT DIVISION. INPUT-OUTPUT SECTION. FILE-CONTROL. SELECT SYSUT1-FILE ASSIGN TO SYSUT1 ORGANIZATION IS SEQUENTIAL ACCESS MODE IS SEQUENTIAL FILE STATUS IS SYSUT1-STATUS. SELECT SYSUT3-FILE ASSIGN TO SYSUT3 ORGANIZATION IS LINE SEQUENTIAL ACCESS MODE IS SEQUENTIAL FILE STATUS IS SYSUT3-STATUS. ***************************************************************** DATA DIVISION. FILE SECTION. FD SYSUT1-FILE DATA RECORD IS SYSUT1-REC . 01 SYSUT1-REC. 05 SYSUT1-DATA-01 PIC X(00512). FD SYSUT3-FILE DATA RECORD IS SYSUT3-REC . 01 SYSUT3-REC. 05 SYSUT3-DATA-01 PIC X(00512). ***************************************************************** * This program was created with the SYSPEKS3.TXT file as the * * template for the File I/O. It is intended for use with the * * Hex Dump facility. * * * * The SYSHEXS3 template provides for the reading of an input * * file (SYSUT1, a sequential file) and the sequential writing * * to an output file (SYSUT2, a sequential file) that contains * * Hexadecimal dump information. * * * * The records to be read from SYSUT1 are defined in a control * * file (SYSUT3) that contains a range of record numbers. * * * * For more information or questions please contact SimoTime * * Technologies. The version control number is 20.00.00 * * * * Our e-mail address is: helpdesk@simotime.com * * Also, visit our Web Site at http://www.simotime.com * ***************************************************************** WORKING-STORAGE SECTION. 01 SIM-TITLE. 05 T1 pic X(11) value '* TCKPEKC1 '. 05 T2 pic X(34) value 'Peek TCKPEKB1 to SYSOUT via SYSUT3'. 05 T3 pic X(10) value ' v23.01.01'. 05 T4 pic X(24) value ' helpdesk@simotime.com'. 01 SIM-COPYRIGHT. 05 C1 pic X(11) value '* TCKPEKC1 '. 05 C2 pic X(32) value 'This Data File FldPEEK Member wa'. 05 C3 pic X(32) value 's generated by SimoTime Technolo'. 05 C4 pic X(04) value 'gies'. 01 SIM-THANKS-01. 05 C1 pic X(11) value '* TCKPEKC1 '. 05 C2 pic X(32) value 'This Data File FldPEEK Member wa'. 05 C3 pic X(32) value 's generated by SimoTime Technolo'. 05 C4 pic X(04) value 'gies'. 01 SIM-THANKS-02. 05 C1 pic X(11) value '* TCKPEKC1 '. 05 C2 pic X(32) value 'Please send all comments or sugg'. 05 C3 pic X(32) value 'estions to the helpdesk@simotime'. 05 C4 pic X(04) value '.com'. 01 SYSUT1-STATUS. 05 SYSUT1-STATUS-L pic X. 05 SYSUT1-STATUS-R pic X. 01 SYSUT1-EOF pic X value 'N'. 01 SYSUT1-OPEN-FLAG pic X value 'C'. 01 SYSUT3-STATUS. 05 SYSUT3-STATUS-L pic X. 05 SYSUT3-STATUS-R pic X. 01 SYSUT3-EOF pic X value 'N'. 01 SYSUT3-OPEN-FLAG pic X value 'C'. 01 SYSUT1-LRECL pic 9(5) value 00512. 01 SYSUT3-LRECL pic 9(5) value 00512. 01 KEY-LEN pic 9(3) value 12. ***************************************************************** * The following buffers are used to create a four-byte status * * code that may be displayed. * ***************************************************************** 01 IO-STATUS. 05 IO-STAT1 pic X. 05 IO-STAT2 pic X. 01 IO-STATUS-04. 05 IO-STATUS-0401 pic 9 value 0. 05 IO-STATUS-0403 pic 999 value 0. 01 TWO-BYTES-BINARY pic 9(4) BINARY. 01 TWO-BYTES-ALPHA redefines TWO-BYTES-BINARY. 05 TWO-BYTES-LEFT pic X. 05 TWO-BYTES-RIGHT pic X. ***************************************************************** * Message Buffer used by the Z-DISPLAY-TO-SYSOUT routine. * ***************************************************************** 01 MESSAGE-BUFFER. 05 MESSAGE-HEADER pic X(011) value '* TCKPEKC1 '. 05 MESSAGE-TEXT. 10 MESSAGE-TEXT-1 pic X(068) value SPACES. 10 MESSAGE-TEXT-2 pic X(188) value SPACES. 01 MSG-LSB pic 9(5) value 267. ***************************************************************** 01 PROGRAM-NAME pic X(8) value 'TCKPEKC1'. 01 INFO-STATEMENT. 05 INFO-SHORT. 10 INFO-ID pic X(8) value 'Starting'. 10 filler pic X(2) value ', '. 10 filler pic X(34) value 'Peek TCKPEKB1 to SYSOUT via SYSUT3'. 05 filler pic X(24) value ' http://www.SimoTime.com'. 01 APPL-RESULT pic S9(9) comp. 88 APPL-AOK value 0. 88 APPL-EOF value 16. 01 PT-1 pic 9(5) value 0. 01 PT-2 pic 9(5) value 0. 01 WORK-05 pic X(5). 01 BN-2-GROUP. 05 BN-2-VALUE pic 9(3) comp value 0. 01 SEQ-GROUP pic 9(4) value 3124. 01 SEQ-TABLE redefines SEQ-GROUP. 05 SEQ-VALUE pic 9 occurs 4 times. 01 SEQ-IX pic 9 value 0. 01 DUMP-FLAGS. 05 DUMP-ASC pic X value 'Y'. 05 DUMP-EBC pic X value 'Y'. 05 DUMP-HEX pic X value 'Y'. 05 DUMP-RPI pic X value 'Y'. 01 YES-YES pic XX value 'YY'. 01 N-BYTE pic X value 'N'. 01 Y-BYTE pic X value 'Y'. 01 GROUP-DELIMITER pic X value 'Y'. 01 RANGE-GROUP. 05 FILLER pic X(11) value '/Range Low='. 05 RANGE-GROUP-LO. 10 RANGE-VALUE-LO pic 9(11) value 1. 05 FILLER pic X(07) value ', High='. 05 RANGE-GROUP-HI. 10 RANGE-VALUE-HI pic 9(11) value 999999999. 01 RA11-GROUP. 05 RA11-VALUE pic 9(11) value 0. 01 RA11-IDX pic 9(5) value 0. 01 TAG11-PARM PIC X(11) value SPACES. 01 RPI-10. 05 RPI-ALPHA pic X(5) value '....:'. 05 RPI-VALUE pic 9(5) value 10. 01 LOOP-REDO pic 9(5) value 0. 01 SYSUT1-TOTAL. 05 SYSUT1-RDR pic 9(9) value 0. 05 filler pic X(3) value ' - '. 05 filler pic X(25) value 'Record count for SYSUT1 '. 01 SYSUT3-TOTAL. 05 SYSUT3-RDR pic 9(9) value 0. 05 filler pic X(3) value ' - '. 05 filler pic X(25) value 'Record count for SYSUT3 '. COPY HEXTAB02. COPY PASSPARS. * USERDATA Definitions not specified. ***************************************************************** PROCEDURE DIVISION. perform JOB-STARTING perform until SYSUT1-STATUS not = '00' perform SYSUT1-READ if SYSUT1-STATUS = '00' add 1 to SYSUT1-RDR if SYSUT1-RDR > RANGE-VALUE-LO or SYSUT1-RDR = RANGE-VALUE-LO if SYSUT1-RDR < RANGE-VALUE-HI or SYSUT1-RDR = RANGE-VALUE-HI move all '-' to MESSAGE-TEXT(1:103) move '*' to MESSAGE-TEXT(1:1) move '*' to MESSAGE-TEXT(103:1) perform Z-DISPLAY-TO-SYSOUT move SYSUT1-TOTAL to MESSAGE-TEXT perform Z-DISPLAY-TO-SYSOUT call 'TCKPEKR1' using SYSUT1-REC end-if end-if end-if end-perform perform JOB-FINISHED GOBACK. ***************************************************************** JOB-FINISHED. perform Z-THANK-YOU. perform SYSUT1-CLOSE exit. ***************************************************************** JOB-STARTING. perform Z-POST-COPYRIGHT perform JOB-STARTING-CNTL perform SYSUT1-OPEN exit. ***************************************************************** JOB-STARTING-CNTL. perform SYSUT3-OPEN if SYSUT3-STATUS = '00' move 'SYSUT3 Opened for User Parameters...' to MESSAGE-TEXT perform Z-DISPLAY-TO-SYSOUT * Prepare control items for parsing. move '0' to PRS-REQUEST add 9 to ZERO giving PRS-STATUS move ' ' to PRS-DELIMITER move 'N' to PRS-TERMINATOR move ' ' to PRS-TERMINATOR-BYTE add 5 to ZERO giving PRS-TABLE-MAX add 80 to ZERO giving PRS-BUFFER-SIZE perform until SYSUT3-STATUS not = '00' perform SYSUT3-READ if SYSUT3-STATUS = '00' move SYSUT3-REC to MESSAGE-TEXT perform Z-DISPLAY-TO-SYSOUT if SYSUT3-REC(1:1) = '/' move SYSUT3-REC to PRS-BUFFER call 'SIMOPARS' using PRS-PARAMETERS perform JOB-STARTING-CNTL-10 end-if end-if end-perform perform SYSUT3-CLOSE else move 'Assume User Defaults for Parameters...' to MESSAGE-TEXT perform Z-DISPLAY-TO-SYSOUT end-if exit. ***************************************************************** JOB-STARTING-CNTL-10. if PRS-POSITION(1) > 0 and PRS-SIZE (1) < 12 move SPACES to TAG11-PARM move SYSUT3-REC(PRS-POSITION(1):PRS-SIZE(1)) to TAG11-PARM evaluate TAG11-PARM when '/RANGE ' perform JOB-STARTING-CNTL-RANGE when other continue end-evaluate end-if exit. ***************************************************************** JOB-STARTING-CNTL-RANGE. if PRS-POSITION(2) > 0 and PRS-SIZE(2) < 12 move SPACES to RA11-GROUP move SYSUT3-REC(PRS-POSITION(2):PRS-SIZE(2)) to RA11-GROUP perform RA11-ADJUST if RA11-VALUE is NUMERIC add RA11-VALUE to ZERO giving RANGE-VALUE-LO else move '/RANGE Parameter-1 is invalid or non-numeric' to MESSAGE-TEXT perform Z-DISPLAY-TO-SYSOUT end-if end-if if PRS-POSITION(3) > 0 and PRS-SIZE(3) < 12 move SPACES to RA11-GROUP move SYSUT3-REC(PRS-POSITION(3):PRS-SIZE(3)) to RA11-GROUP perform RA11-ADJUST if RA11-VALUE is NUMERIC add RA11-VALUE to ZERO giving RANGE-VALUE-HI else move '/RANGE Parameter-2 is invalid or non-numeric' to MESSAGE-TEXT perform Z-DISPLAY-TO-SYSOUT end-if end-if move RANGE-GROUP to MESSAGE-TEXT perform Z-DISPLAY-TO-SYSOUT exit. ***************************************************************** RA11-ADJUST. perform until RA11-GROUP(11:1) not = SPACE add 10 to ZERO giving RA11-IDX perform until RA11-IDX = 0 move RA11-GROUP(RA11-IDX:1) to RA11-GROUP(RA11-IDX + 1:1) subtract 1 from RA11-IDX end-perform move '0' to RA11-GROUP(1:1) end-perform exit. ***************************************************************** * I/O Routines for the INPUT File... * ***************************************************************** SYSUT1-CLOSE. add 8 to ZERO giving APPL-RESULT. close SYSUT1-FILE if SYSUT1-STATUS = '00' subtract APPL-RESULT from APPL-RESULT else add 12 to ZERO giving APPL-RESULT end-if if APPL-AOK CONTINUE else move 'CLOSE Failure with SYSUT1 ' to MESSAGE-TEXT perform Z-DISPLAY-TO-SYSOUT move SYSUT1-STATUS to IO-STATUS perform Z-DISPLAY-IO-STATUS perform Z-ABEND-PROGRAM end-if exit. *---------------------------------------------------------------* SYSUT1-READ. read SYSUT1-FILE if SYSUT1-STATUS = '00' subtract APPL-RESULT from APPL-RESULT else if SYSUT1-STATUS = '10' add 16 to ZERO giving APPL-RESULT else add 12 to ZERO giving APPL-RESULT end-if end-if if APPL-AOK CONTINUE else if APPL-EOF move 'Y' to SYSUT1-EOF else move 'READ Failure with SYSUT1 ' to MESSAGE-TEXT perform Z-DISPLAY-TO-SYSOUT move SYSUT1-STATUS to IO-STATUS perform Z-DISPLAY-IO-STATUS * perform Z-ABEND-PROGRAM end-if end-if exit. *---------------------------------------------------------------* SYSUT1-OPEN. add 8 to ZERO giving APPL-RESULT. open input SYSUT1-FILE if SYSUT1-STATUS = '00' subtract APPL-RESULT from APPL-RESULT move 'O' to SYSUT1-OPEN-FLAG else add 12 to ZERO giving APPL-RESULT end-if if APPL-AOK CONTINUE else move 'OPEN Failure with SYSUT1 ' to MESSAGE-TEXT perform Z-DISPLAY-TO-SYSOUT move SYSUT1-STATUS to IO-STATUS perform Z-DISPLAY-IO-STATUS perform Z-ABEND-PROGRAM end-if exit. ***************************************************************** * I/O Routines for the Control or Parameter File... * ***************************************************************** SYSUT3-READ. read SYSUT3-FILE if SYSUT3-STATUS = '00' subtract APPL-RESULT from APPL-RESULT add 1 to SYSUT3-RDR else if SYSUT3-STATUS = '10' add 16 to ZERO giving APPL-RESULT else add 12 to ZERO giving APPL-RESULT end-if end-if. if APPL-AOK CONTINUE else if APPL-EOF move 'Y' to SYSUT3-EOF else move 'READ Failure with SYSUT3 ' to MESSAGE-TEXT perform Z-DISPLAY-TO-SYSOUT move SYSUT3-STATUS to IO-STATUS perform Z-DISPLAY-IO-STATUS perform Z-ABEND-PROGRAM end-if end-if exit. *---------------------------------------------------------------* SYSUT3-OPEN. add 8 to ZERO giving APPL-RESULT. open input SYSUT3-FILE if SYSUT3-STATUS = '00' subtract APPL-RESULT from APPL-RESULT move 'O' to SYSUT3-OPEN-FLAG else add 12 to ZERO giving APPL-RESULT end-if if APPL-AOK CONTINUE else move 'OPEN Failure with SYSUT3 ' to MESSAGE-TEXT perform Z-DISPLAY-TO-CONSOLE perform Z-DISPLAY-TO-SYSOUT move SYSUT3-STATUS to IO-STATUS perform Z-DISPLAY-IO-STATUS end-if exit. *---------------------------------------------------------------* SYSUT3-CLOSE. add 8 to ZERO giving APPL-RESULT. close SYSUT3-FILE if SYSUT3-STATUS = '00' subtract APPL-RESULT from APPL-RESULT move 'C' to SYSUT3-OPEN-FLAG else add 12 to ZERO giving APPL-RESULT end-if if APPL-AOK CONTINUE else move 'CLOSE Failure with SYSUT3 ' to MESSAGE-TEXT perform Z-DISPLAY-TO-SYSOUT move SYSUT3-STATUS to IO-STATUS perform Z-DISPLAY-IO-STATUS perform Z-ABEND-PROGRAM end-if exit. ***************************************************************** * The following Z-ROUTINES provide administrative functions * * for this program. * ***************************************************************** * ABEND the program, post a message to the console and issue * * a STOP RUN. * ***************************************************************** Z-ABEND-PROGRAM. if MESSAGE-TEXT not = SPACES perform Z-DISPLAY-TO-SYSOUT end-if move 'PROGRAM-IS-ABENDING...' to MESSAGE-TEXT perform Z-DISPLAY-TO-SYSOUT add 12 to ZERO giving RETURN-CODE STOP RUN. * exit. ***************************************************************** Z-CALCULATE-MESSAGE-LSB. add 267 to ZERO giving MSG-LSB perform until MSG-LSB < 80 or MESSAGE-BUFFER(MSG-LSB:1) not = SPACE if MESSAGE-BUFFER(MSG-LSB:1) = SPACE subtract 1 from MSG-LSB end-if end-perform exit. ***************************************************************** * Display CONSOLE messages... * ***************************************************************** Z-DISPLAY-TO-SYSOUT. perform Z-CALCULATE-MESSAGE-LSB display MESSAGE-BUFFER(1:MSG-LSB) move all SPACES to MESSAGE-TEXT exit. ***************************************************************** * Display CONSOLE messages... * ***************************************************************** Z-DISPLAY-TO-CONSOLE. perform Z-CALCULATE-MESSAGE-LSB if MESSAGE-TEXT-2 = SPACES display MESSAGE-BUFFER(1:MSG-LSB) upon console exit. ***************************************************************** * Display the file status bytes. This routine will display as * * four digits. If the full two byte file status is numeric it * * will display as 00nn. If the 1st byte is a numeric nine (9) * * the second byte will be treated as a binary number and will * * display as 9nnn. * ***************************************************************** Z-DISPLAY-IO-STATUS. if IO-STATUS not NUMERIC or IO-STAT1 = '9' move IO-STAT1 to IO-STATUS-04(1:1) subtract TWO-BYTES-BINARY from TWO-BYTES-BINARY move IO-STAT2 to TWO-BYTES-RIGHT add TWO-BYTES-BINARY to ZERO giving IO-STATUS-0403 move 'File Status is: nnnn' to MESSAGE-TEXT move IO-STATUS-04 to MESSAGE-TEXT(17:4) perform Z-DISPLAY-TO-SYSOUT else move '0000' to IO-STATUS-04 move IO-STATUS to IO-STATUS-04(3:2) move 'File Status is: nnnn' to MESSAGE-TEXT move IO-STATUS-04 to MESSAGE-TEXT(17:4) perform Z-DISPLAY-TO-SYSOUT end-if exit. ***************************************************************** Z-POST-COPYRIGHT. display SIM-TITLE display SIM-COPYRIGHT exit. ***************************************************************** Z-THANK-YOU. move SIM-THANKS-01 to MESSAGE-BUFFER perform Z-DISPLAY-TO-SYSOUT move SIM-THANKS-02 to MESSAGE-BUFFER perform Z-DISPLAY-TO-SYSOUT exit. ***************************************************************** * This program was generated by SimoZAPS * * A product of SimoTime Technologies * * Our e-mail address is: helpdesk@simotime.com * * Also, visit our Web Site at http://www.simotime.com * * * * Generation Date: 2023-03-03 Generation Time: 21:06:07:32 * *****************************************************************
This document shows the content of a COBOL Source Member. This document may be used to assist as a tutorial for new programmers or as a quick reference for experienced programmers.
In the world of programming there are many ways to solve a problem. This documentation and software were developed and tested on systems that are configured for a SIMOTIME environment based on the hardware, operating systems, user requirements and security requirements. Therefore, adjustments may be needed to execute the jobs and programs when transferred to a system of a different architecture or configuration.
SIMOTIME Services has experience in moving or sharing data or application processing across a variety of systems. For additional information about SIMOTIME Services or Technologies please contact us using the information in the Contact, Comment or Feedback section of this document.
Software Agreement and Disclaimer
Permission to use, copy, modify and distribute this software, documentation or training material for any purpose requires a fee to be paid to SimoTime Technologies. Once the fee is received by SimoTime the latest version of the software, documentation or training material will be delivered and a license will be granted for use within an enterprise, provided the SimoTime copyright notice appear on all copies of the software. The SimoTime name or Logo may not be used in any advertising or publicity pertaining to the use of the software without the written permission of SimoTime Technologies.
SimoTime Technologies makes no warranty or representations about the suitability of the software, documentation or learning material for any purpose. It is provided "AS IS" without any expressed or implied warranty, including the implied warranties of merchantability, fitness for a particular purpose and non-infringement. SimoTime Technologies shall not be liable for any direct, indirect, special or consequential damages resulting from the loss of use, data or projects, whether in an action of contract or tort, arising out of or in connection with the use or performance of this software, documentation or training material.
This section includes links to documents with additional information that are beyond the scope and purpose of this document. The first group of documents may be available from a local system or via an Internet connection, the second group of documents will require an Internet connection.
Note: A SIMOTIME License is required for the items to be made available on a local system or server.
The following links may be to the current server or to the Internet.
Note: The latest versions of the SimoTime Documents and Program Suites are available on the Internet and may be accessed using the icon. If a user has a SimoTime Enterprise License the Documents and Program Suites may be available on a local server and accessed using the icon.
Explore An Enterprise System Model that describes and demonstrates how Applications that were running on a Mainframe System and non-relational data that was located on the Mainframe System were copied and deployed in a Microsoft Windows environment with Micro Focus Enterprise Server.
Explore The Binary or COMP format for numeric data strings. This numeric structure is supported by COBOL and may be explicitly defined with the "USAGE IS COMP" or "USAGE IS BINARY" clause.
Explore The Packed-Decimal or COMP-3 format for numeric data strings. This numeric structure is supported by COBOL and may be explicitly defined with the "USAGE IS COMP-3" clause.
Explore The Zoned-Decimal format for numeric data strings. This numeric structure is the default numeric for COBOL and may be explicitly defined with the "USAGE IS DISPLAY" clause.
Explore How to Generate a Data File Convert Program using simple specification statements in a Process Control File (PCF). This link to the User Guide includes the information necessary to create a Process Control File and generate the COBOL programs that will do the actual data file conversion. The User Guide contains a list of the PCF statements that are used for the data file convert process.
Explore How to Generate a Data File Compare, Validate or Hex-Dump Program using simple specification statements in a Process Control File (PCF). This link to the User Guide includes the information necessary to create a Process Control File and generate the COBOL programs that will do a data file compare, accumulate summary totals with a record count or produce a Hex-Dump of records in a VSAM, KSDS based on a list of user-defined keys. The User Guide contains a list of the PCF statements that are used for the data file compare, validate or dump process.
Explore the COBOL Connection for more examples of COBOL programming techniques and sample code.
Explore The ASCII and EBCDIC Translation Tables. These tables are provided for individuals that need to better understand the bit structures and differences of the encoding formats.
Explore The File Status Return Codes to interpret the results of accessing VSAM data sets and/or QSAM files.
The following links will require an Internet connection.
A good place to start is The SimoTime Home Page for access to white papers, program examples and product information. This link requires an Internet Connection
Explore The Micro Focus Web Site for more information about products (including Micro Focus COBOL) and services available from Micro Focus. This link requires an Internet Connection.
Explore the GnuCOBOL Technologies available from SourceForge. SourceForge is an Open Source community resource dedicated to helping open source projects be as successful as possible. GnuCOBOL (formerly OpenCOBOL) is a COBOL compiler with run time support. The compiler (cobc) translates COBOL source to executable using intermediate C, designated C compiler and linker. This link will require an Internet Connection.
Explore the Glossary of Terms for a list of terms and definitions used in this suite of documents and white papers.
This document was created and is maintained by SimoTime Technologies and Services. If you have any questions, suggestions, comments or feedback please use the following contact information.
1. | Send an e-mail to our helpdesk. |
1.1. | helpdesk@simotime.com. |
2. | Our telephone numbers are as follows. |
2.1. | 1 415 763-9430 office-helpdesk |
2.2. | 1 415 827-7045 mobile |
We appreciate hearing from you.
SimoTime Technologies was founded in 1987 and is a privately owned company. We specialize in the creation and deployment of business applications using new or existing technologies and services. We have a team of individuals that understand the broad range of technologies being used in today's environments. Our customers include small businesses using Internet technologies to corporations using very large mainframe systems.
Quite often, to reach larger markets or provide a higher level of service to existing customers it requires the newer Internet technologies to work in a complementary manner with existing corporate mainframe systems. We specialize in preparing applications and the associated data that are currently residing on a single platform to be distributed across a variety of platforms.
Preparing the application programs will require the transfer of source members that will be compiled and deployed on the target platform. The data will need to be transferred between the systems and may need to be converted and validated at various stages within the process. SimoTime has the technology, services and experience to assist in the application and data management tasks involved with doing business in a multi-system environment.
Whether you want to use the Internet to expand into new market segments or as a delivery vehicle for existing business functions simply give us a call or check the web site at http://www.simotime.com
Return-to-Top |
TCKPEKC1.cbl - COBOL Source Member |
Copyright © 1987-2023 SimoTime Technologies and Services All Rights Reserved |
When technology complements business |
http://www.simotime.com |