Record Concatenation
SIMO801K - The COBOL Source Code
  Table of Contents  v-19.00.00 - simo801k.htm 
  Introduction
  SIMO801K, What It Does
  SIMO801K, How To Use
  The COBOL Source Code
  Summary
  Software Agreement and Disclaimer
  Downloads and Links
  Current Server or Internet Access
  Internet Access Required
  Glossary of Terms
  Comments or Feedback
  Company Overview
The SimoTime Home Page 

Table of Contents Previous Section Next Section Introduction

The SIMO801K Utility Program will concatenate text strings from multiple 80-byte records into a single record with a 1024 byte record length.

This program provides the programmer with the ability to concatenate text strings within multiple 80-byte records into a single 1024-byte record. For an example of a program that calls this routine refer to the Current Server or Internet Access section of this document.

This document provides a listing of the COBOL source code for the SIMO801K utility program. Additional information about this program may be obtained by sending an e-mail to: helpdesk@simotime.com


We have made a significant effort to ensure the documents and software technologies are correct and accurate. We reserve the right to make changes without notice at any time. The function delivered in this version is based upon the enhancement requests from a specific group of users. The intent is to provide changes as the need arises and in a timeframe that is dependent upon the availability of resources.

Copyright © 1987-2024
SimoTime Technologies and Services
All Rights Reserved

Table of Contents Previous Section Next Section SIMO801K, What It Does

The SIMO801K Utility Program will read a sequential file with 80-byte records. Position 72 of the record is used as a continuation indicator. A non-space character will cause positions 1-71 to be moved to the output buffer but the write will be suppressed. The next record will be concatenated with data already in the output buffer. The output file is a Record Sequential file (RSEQ) with a record length of 1,024 bytes.

Table of Contents Previous Section Next Section SIMO801K, How To Use

wip

Table of Contents Previous Section Next Section The COBOL Source Code

The following (SIMO801K.cbl) is the COBOL Source Code.

       IDENTIFICATION DIVISION.
       PROGRAM-ID.    SIMO801K.
       AUTHOR.        SIMOTIME TECHNOLOGIES.
      *****************************************************************
      *           This program was generated by SimoZAPS              *
      *             A product of SimoTime Technologies                *
      *        Our e-mail address is: helpdesk@simotime.com           *
      *     Also, visit our Web Site at http://www.simotime.com       *
      *                                                               *
      *  Generation Date: 2015-10-28  Generation Time: 23:58:40:43    *
      *                                                               *
      *                                   Record    Record     Key    *
      *  Function  Name     Organization  Format    Max-Min  Pos-Len  *
      *  PRIMARY   SYSUT1   SEQUENTIAL    FIXED      00080            *
      *                                                               *
      *  SECONDARY SYSUT2   SEQUENTIAL    FIXED      01024            *
      *                                                               *
      *                                                               *
      *            Translation Mode is User Defined                   *
      *                                                               *
      *****************************************************************
       ENVIRONMENT DIVISION.
       INPUT-OUTPUT SECTION.
       FILE-CONTROL.
           SELECT SYSUT1-FILE  ASSIGN TO       SYSUT1
                  ORGANIZATION  IS SEQUENTIAL
                  ACCESS MODE   IS SEQUENTIAL
                  FILE STATUS   IS SYSUT1-STATUS.
           SELECT SYSUT2-FILE  ASSIGN TO       SYSUT2
                  ORGANIZATION  IS SEQUENTIAL
                  ACCESS MODE   IS SEQUENTIAL
                  FILE STATUS   IS SYSUT2-STATUS.

      *****************************************************************
       DATA DIVISION.
       FILE SECTION.
       FD  SYSUT1-FILE
           DATA RECORD    IS SYSUT1-REC
           .
       01  SYSUT1-REC.
           05  SYSUT1-DATA-01 PIC X(00080).

       FD  SYSUT2-FILE
           DATA RECORD    IS SYSUT2-REC
           .
       01  SYSUT2-REC.
           05  SYSUT2-DATA-01 PIC X(01024).

      *****************************************************************
      * This program was created with the SYSMASK1.TXT file as input. *
      * The SYSMASK1 provides for the sequential reading of the input *
      * file and the sequential writing of the output file.           *
      *                                                               *
      * If the output file is indexed then the input file must be in  *
      * sequence by the field that will be used to provide the key    *
      * for the output file. This is a sequential load process.       *
      *                                                               *
      * If the key field is not in sequence then refer to SYSMASK2    *
      * to provide for a random add or update of the indexed file.    *
      *                                                               *
      * This program mask will have the ASCII/EBCDIC table inserted   *
      * for use by the /TRANSLATE function of SimoZAPS.               *
      *                                                               *
      * For additional information contact SimoTime Technologies.     *
      *        Our e-mail address is: helpdesk@simotime.com           *
      *     Also, visit our Web Site at http://www.simotime.com       *
      *****************************************************************
       WORKING-STORAGE SECTION.
       01  SIM-TITLE.
           05  T1 pic X(11) value '* SIMO801K '.
           05  T2 pic X(34) value 'RSEQ, 80-1024 String Concatenation'.
           05  T3 pic X(10) value ' v15.10.31'.
           05  T4 pic X(24) value '   helpdesk@simotime.com'.
       01  SIM-COPYRIGHT.
           05  C1 pic X(11) value '* SIMO801K '.
           05  C2 pic X(32) value 'This Data File Convert Member wa'.
           05  C3 pic X(32) value 's generated by SimoTime Technolo'.
           05  C4 pic X(04) value 'gies'.

       01  SYSUT1-STATUS.
           05  SYSUT1-STATUS-L     pic X.
           05  SYSUT1-STATUS-R     pic X.
       01  SYSUT1-EOF              pic X       value 'N'.
       01  SYSUT1-OPEN-FLAG        pic X       value 'C'.

       01  SYSUT2-STATUS.
           05  SYSUT2-STATUS-L     pic X.
           05  SYSUT2-STATUS-R     pic X.
       01  SYSUT2-EOF              pic X       value 'N'.
       01  SYSUT2-OPEN-FLAG        pic X       value 'C'.

       01  SYSUT1-LRECL            pic 9(5)    value 00080.
       01  SYSUT2-LRECL            pic 9(5)    value 01024.
       01  SYSUT1-LRECL-MAX        pic 9(5)    value 00080.

      *****************************************************************
      * The following buffers are used to create a four-byte status   *
      * code that may be displayed.                                   *
      *****************************************************************
       01  IO-STATUS.
           05  IO-STAT1            pic X.
           05  IO-STAT2            pic X.
       01  IO-STATUS-04.
           05  IO-STATUS-0401      pic 9     value 0.
           05  IO-STATUS-0403      pic 999   value 0.
       01  TWO-BYTES-BINARY        pic 9(4)  BINARY.
       01  TWO-BYTES-ALPHA         redefines TWO-BYTES-BINARY.
           05  TWO-BYTES-LEFT      pic X.
           05  TWO-BYTES-RIGHT     pic X.

      *****************************************************************
      * Message Buffer used by the Z-DISPLAY-MESSAGE-TEXT routine.    *
      *****************************************************************
       01  MESSAGE-BUFFER.
           05  MESSAGE-HEADER      pic X(11)   value '* SIMO801K '.
           05  MESSAGE-TEXT.
               10  MESSAGE-TEXT-1  pic X(68)   value SPACES.
               10  MESSAGE-TEXT-2  pic X(188)  value SPACES.

      *****************************************************************
       01  PROGRAM-NAME            pic X(8)     value 'SIMO801K'.

       01  INFO-STATEMENT.
           05  INFO-SHORT.
               10  INFO-ID pic X(8)    value 'Starting'.
               10  filler  pic X(2)    value ', '.
               10  filler  pic X(34)
                   value   'RSEQ, 80-1024 String Concatenation'.
           05  filler      pic X(24)
               value ' http://www.SimoTime.com'.

       01  APPL-RESULT             pic S9(9)    comp.
           88  APPL-AOK            value 0.
           88  APPL-EOF            value 16.

       01  WRITE-FLAG      pic X       value 'Y'.

       01  SYSUT1-TOTAL.
           05  SYSUT1-RDR  pic 9(9)    value 0.
           05  filler      pic X(3)    value ' - '.
           05  filler      pic X(23)   value 'Line count for SYSUT1  '.
       01  SYSUT2-TOTAL.
           05  SYSUT2-ADD  pic 9(9)    value 0.
           05  filler      pic X(3)    value ' - '.
           05  filler      pic X(23)   value 'Line count for SYSUT2  '.

      *****************************************************************
      *    User defined working storage...
      *    USERDATA       SIMO801K_CRT_WS.inc
       01  NEXT-PUT-POSN               PIC 9(5)    value 1.
       01  LAST-GET-SIG-POSN           PIC 9(5)    value 71.
       01  PT-1                        PIC 9(5)    value 1.

      *****************************************************************
       PROCEDURE DIVISION.
           move all '*' to MESSAGE-TEXT-1
           perform Z-DISPLAY-MESSAGE-TEXT
           move INFO-STATEMENT to MESSAGE-TEXT-1
           perform Z-DISPLAY-MESSAGE-TEXT
           move all '*' to MESSAGE-TEXT-1
           perform Z-DISPLAY-MESSAGE-TEXT
           perform Z-POST-COPYRIGHT
           perform SYSUT1-OPEN
           perform SYSUT2-OPEN

           perform until SYSUT1-STATUS not = '00'
               move SPACES to SYSUT1-REC
               perform SYSUT1-READ
               if  SYSUT1-STATUS = '00'
                   add 1 to SYSUT1-RDR
                   perform BUILD-OUTPUT-RECORD
                   if  WRITE-FLAG = 'Y'
                       perform SYSUT2-WRITE
                       if  SYSUT2-STATUS = '00'
                           add 1 to SYSUT2-ADD
                       end-if
                   end-if
               end-if
           end-perform

      *    USREOJ Processing not specified...

           move SYSUT1-TOTAL to MESSAGE-TEXT
           perform Z-DISPLAY-MESSAGE-TEXT

           move SYSUT2-TOTAL to MESSAGE-TEXT
           perform Z-DISPLAY-MESSAGE-TEXT

           if  APPL-EOF
               move 'Complete' to INFO-ID
           else
               move 'ABENDING' to INFO-ID
           end-if
           move INFO-STATEMENT to MESSAGE-TEXT(1:79)
           perform Z-DISPLAY-MESSAGE-TEXT

           perform SYSUT2-CLOSE
           perform SYSUT1-CLOSE
           GOBACK.

      *****************************************************************
       BUILD-OUTPUT-RECORD.
      *    USEREXEC *INC  SIMO801K_CRT_UI.inc
      *****************************************************************
      * EYE CATCHER for SIMO801K
           if  WRITE-FLAG = 'Y'
               move SPACES to SYSUT2-DATA-01
           end-if
           perform USER-SYSUT1-LSB
           if  SYSUT1-DATA-01(72:1) = SPACE
               move SYSUT1-DATA-01
                 to SYSUT2-DATA-01(NEXT-PUT-POSN:LAST-GET-SIG-POSN)
               move 'Y' to WRITE-FLAG
               add  1 to ZERO giving NEXT-PUT-POSN
           else
               move SYSUT1-DATA-01(1:LAST-GET-SIG-POSN)
                 to SYSUT2-DATA-01(NEXT-PUT-POSN:LAST-GET-SIG-POSN)
               move 'N' to WRITE-FLAG
               add LAST-GET-SIG-POSN to NEXT-PUT-POSN
           exit.

      *****************************************************************
       USER-SYSUT1-LSB.
           add 1 to ZERO giving PT-1
           add 1 to ZERO giving LAST-GET-SIG-POSN
           perform 71 times
             if  SYSUT1-DATA-01(PT-1:1) not = SPACE
                 add PT-1 to ZERO giving LAST-GET-SIG-POSN
             end-if
             add 1 to PT-1
           end-perform
           exit.

      *****************************************************************
      * I/O Routines for the INPUT File...                            *
      *****************************************************************
       SYSUT1-CLOSE.
           add 8 to ZERO giving APPL-RESULT.
           close SYSUT1-FILE
           if  SYSUT1-STATUS = '00'
               subtract APPL-RESULT from APPL-RESULT
           else
               add 4 to ZERO giving APPL-RESULT
           end-if
           if  APPL-AOK
               CONTINUE
           else
               move 'CLOSE Failure with SYSUT1  ' to MESSAGE-TEXT
               perform Z-DISPLAY-MESSAGE-TEXT
               move SYSUT1-STATUS to IO-STATUS
               perform Z-DISPLAY-IO-STATUS
               perform Z-ABEND-PROGRAM
           end-if
           exit.
      *---------------------------------------------------------------*
       SYSUT1-READ.
           read SYSUT1-FILE
           if  SYSUT1-STATUS = '00'
               subtract APPL-RESULT from APPL-RESULT
           else
               if  SYSUT1-STATUS = '10'
                   add 16 to ZERO giving APPL-RESULT
               else
                   add 12 to ZERO giving APPL-RESULT
               end-if
           end-if
           if  APPL-AOK
               CONTINUE
           else
               if  APPL-EOF
                   move 'Y' to SYSUT1-EOF
               else
                   move 'READ Failure with SYSUT1  ' to MESSAGE-TEXT
                   perform Z-DISPLAY-MESSAGE-TEXT
                   move SYSUT1-STATUS to IO-STATUS
                   perform Z-DISPLAY-IO-STATUS
                   perform Z-ABEND-PROGRAM
               end-if
           end-if
           exit.
      *---------------------------------------------------------------*
       SYSUT1-OPEN.
           add 8 to ZERO giving APPL-RESULT.
           open input SYSUT1-FILE
           if  SYSUT1-STATUS = '00'
               subtract APPL-RESULT from APPL-RESULT
               move 'O' to SYSUT1-OPEN-FLAG
           else
               add 16 to ZERO giving APPL-RESULT
           end-if
           if  APPL-AOK
               CONTINUE
           else
               move 'OPEN Failure with SYSUT1  ' to MESSAGE-TEXT
               perform Z-DISPLAY-MESSAGE-TEXT
               move SYSUT1-STATUS to IO-STATUS
               perform Z-DISPLAY-IO-STATUS
               perform Z-ABEND-PROGRAM
           end-if
           exit.

      *****************************************************************
      * I/O Routines for the OUTPUT File...                           *
      *****************************************************************
       SYSUT2-WRITE.
           if  SYSUT2-OPEN-FLAG = 'C'
               perform SYSUT2-OPEN
           end-if
           write SYSUT2-REC
           if  SYSUT2-STATUS = '00'
               subtract APPL-RESULT from APPL-RESULT
           else
               if  SYSUT2-STATUS = '10'
                   add 16 to ZERO giving APPL-RESULT
               else
                   add 12 to ZERO giving APPL-RESULT
               end-if
           end-if.
           if  APPL-AOK
               CONTINUE
           else
               move 'WRITE Failure with SYSUT2  ' to MESSAGE-TEXT
               perform Z-DISPLAY-MESSAGE-TEXT
               move SYSUT2-STATUS to IO-STATUS
               perform Z-DISPLAY-IO-STATUS
               perform Z-ABEND-PROGRAM
           end-if
           exit.
      *---------------------------------------------------------------*
       SYSUT2-OPEN.
           add 8 to ZERO giving APPL-RESULT.
           open OUTPUT SYSUT2-FILE
           if  SYSUT2-STATUS = '00'
               subtract APPL-RESULT from APPL-RESULT
               move 'O' to SYSUT2-OPEN-FLAG
           else
               add 12 to ZERO giving APPL-RESULT
           end-if
           if  APPL-AOK
               CONTINUE
           else
               move 'OPEN Failure with SYSUT2  ' to MESSAGE-TEXT
               perform Z-DISPLAY-MESSAGE-TEXT
               move SYSUT2-STATUS to IO-STATUS
               perform Z-DISPLAY-IO-STATUS
               perform Z-ABEND-PROGRAM
           end-if
           exit.
      *---------------------------------------------------------------*
       SYSUT2-CLOSE.
           add 8 to ZERO giving APPL-RESULT.
           close SYSUT2-FILE
           if  SYSUT2-STATUS = '00'
               subtract APPL-RESULT from APPL-RESULT
               move 'C' to SYSUT2-OPEN-FLAG
           else
               add 12 to ZERO giving APPL-RESULT
           end-if
           if  APPL-AOK
               CONTINUE
           else
               move 'CLOSE Failure with SYSUT2  ' to MESSAGE-TEXT
               perform Z-DISPLAY-MESSAGE-TEXT
               move SYSUT2-STATUS to IO-STATUS
               perform Z-DISPLAY-IO-STATUS
               perform Z-ABEND-PROGRAM
           end-if
           exit.

      *****************************************************************
      * The following Z-ROUTINES provide administrative functions     *
      * for this program.                                             *
      *****************************************************************
      * ABEND the program, post a message to the console and issue    *
      * a STOP RUN.                                                   *
      *****************************************************************
       Z-ABEND-PROGRAM.
           if  MESSAGE-TEXT not = SPACES
               perform Z-DISPLAY-MESSAGE-TEXT
           end-if
           move 'PROGRAM-IS-ABENDING...'  to MESSAGE-TEXT
           perform Z-DISPLAY-MESSAGE-TEXT
           add 12 to ZERO giving RETURN-CODE
           STOP RUN.
      *    exit.

      *****************************************************************
      * Display CONSOLE messages...                                   *
      *****************************************************************
       Z-DISPLAY-MESSAGE-TEXT.
           if MESSAGE-TEXT-2 = SPACES
               display MESSAGE-BUFFER(1:79)
           else
               display MESSAGE-BUFFER
           end-if
           move all SPACES to MESSAGE-TEXT
           exit.

      *****************************************************************
      * Display the file status bytes. This routine will display as   *
      * four digits. If the full two byte file status is numeric it   *
      * will display as 00nn. If the 1st byte is a numeric nine (9)   *
      * the second byte will be treated as a binary number and will   *
      * display as 9nnn.                                              *
      *****************************************************************
       Z-DISPLAY-IO-STATUS.
           if  IO-STATUS not NUMERIC
           or  IO-STAT1 = '9'
               move IO-STAT1 to IO-STATUS-04(1:1)
               subtract TWO-BYTES-BINARY from TWO-BYTES-BINARY
               move IO-STAT2 to TWO-BYTES-RIGHT
               add TWO-BYTES-BINARY to ZERO giving IO-STATUS-0403
               move 'File Status is: nnnn' to MESSAGE-TEXT
               move IO-STATUS-04 to MESSAGE-TEXT(17:4)
               perform Z-DISPLAY-MESSAGE-TEXT
           else
               move '0000' to IO-STATUS-04
               move IO-STATUS to IO-STATUS-04(3:2)
               move 'File Status is: nnnn' to MESSAGE-TEXT
               move IO-STATUS-04 to MESSAGE-TEXT(17:4)
               perform Z-DISPLAY-MESSAGE-TEXT
           end-if
           exit.

      *****************************************************************
       Z-POST-COPYRIGHT.
           display SIM-TITLE
           display SIM-COPYRIGHT
           exit.
      *****************************************************************
      *           This program was generated by SimoZAPS              *
      *             A product of SimoTime Technologies                *
      *        Our e-mail address is: helpdesk@simotime.com           *
      *     Also, visit our Web Site at http://www.simotime.com       *
      *                                                               *
      *  Generation Date: 2015-10-28  Generation Time: 23:58:40:48    *
      *****************************************************************

Table of Contents Previous Section Next Section Summary

The SIMO801K program will concatenate text strings from multiple 80-byte records into a single record with a 1024 byte record length. This document may be used as a tutorial for new programmers or as a quick reference for experienced programmers.

In the world of programming there are many ways to solve a problem. This documentation and software were developed and tested on systems that are configured for a SIMOTIME environment based on the hardware, operating systems, user requirements and security requirements. Therefore, adjustments may be needed to execute the jobs and programs when transferred to a system of a different architecture or configuration.

SIMOTIME Services has experience in moving or sharing data or application processing across a variety of systems. For additional information about SIMOTIME Services or Technologies please contact us using the information in the  Contact, Comment or Feedback  section of this document.

Table of Contents Previous Section Next Section Software Agreement and Disclaimer

Permission to use, copy, modify and distribute this software, documentation or training material for any purpose requires a fee to be paid to SimoTime Technologies. Once the fee is received by SimoTime the latest version of the software, documentation or training material will be delivered and a license will be granted for use within an enterprise, provided the SimoTime copyright notice appear on all copies of the software. The SimoTime name or Logo may not be used in any advertising or publicity pertaining to the use of the software without the written permission of SimoTime Technologies.

SimoTime Technologies makes no warranty or representations about the suitability of the software, documentation or learning material for any purpose. It is provided "AS IS" without any expressed or implied warranty, including the implied warranties of merchantability, fitness for a particular purpose and non-infringement. SimoTime Technologies shall not be liable for any direct, indirect, special or consequential damages resulting from the loss of use, data or projects, whether in an action of contract or tort, arising out of or in connection with the use or performance of this software, documentation or training material.

Table of Contents Previous Section Next Section Downloads and Links

This section includes links to documents with additional information that are beyond the scope and purpose of this document. The first group of documents may be available from a local system or via an internet connection, the second group of documents will require an internet connection.

Note: A SimoTime License is required for the items to be made available on a local system or server.

Table of Contents Previous Section Next Section Current Server or Internet Access

The following links may be to the current server or to the Internet.

Note: The latest versions of the SimoTime Documents and Program Suites are available on the Internet and may be accessed using the Link to Internet icon. If a user has a SimoTime Enterprise License the Documents and Program Suites may be available on a local server and accessed using the Link to Server icon.

Link to Internet   Link to Server   Explore How to do Case Conversion using COBOL. The example shows a simple conversion between upper and lower case plus capitalization and editing of specific words within a text string. The mainline program will call the SIMOCASE module that is available from SimoTime as part of the SIMOMODS package.

Link to Internet   Link to Server   Explore a complete list of the SimoTime Callable Routines or Utility Programs. This includes the callable routines and utility programs for the Micro Focus environment.

Link to Internet   Link to Server   Explore An Enterprise System Model that describes and demonstrates how Applications that were running on a Mainframe System and non-relational data that was located on the Mainframe System were copied and deployed in a Microsoft Windows environment with Micro Focus Enterprise Server.

Link to Internet   Link to Server   Explore The ASCII and EBCDIC Translation Tables. These tables are provided for individuals that need to better understand the bit structures and differences of the encoding formats.

Link to Internet   Link to Server   Explore The File Status Return Codes that are used to interpret the results of accessing VSAM data sets and/or QSAM files.

Table of Contents Previous Section Next Section Internet Access Required

The following links will require an internet connect.

This suite of programs and documentation is available to download for review and evaluation purposes. Other uses will require a SimoTime Software License. Link to an Evaluation zPAK Option that includes the program members, documentation and control files.

A good place to start is The SimoTime Home Page for access to white papers, program examples and product information. This link requires an Internet Connection

Explore The Micro Focus Web Site for more information about products (including Micro Focus COBOL) and services available from Micro Focus. This link requires an Internet Connection.

Explore the GnuCOBOL Technologies available from SourceForge. SourceForge is an Open Source community resource dedicated to helping open source projects be as successful as possible. GnuCOBOL (formerly OpenCOBOL) is a COBOL compiler with run time support. The compiler (cobc) translates COBOL source to executable using intermediate C, designated C compiler and linker. This link will require an Internet Connection.

Table of Contents Previous Section Next Section Glossary of Terms

Link to Internet   Link to Server   Explore the Glossary of Terms for a list of terms and definitions used in this suite of documents and white papers.

Table of Contents Previous Section Next Section Comments or Feedback

This document was created and is maintained by SimoTime Technologies. If you have any questions, suggestions, comments or feedback please use the following contact information.

1. Send an e-mail to our helpdesk.
1.1. helpdesk@simotime.com.
2. Our telephone numbers are as follows.
2.1. 1 415 763-9430 office-helpdesk
2.2. 1 415 827-7045 mobile

 

We appreciate hearing from you.

Table of Contents Previous Section Next Section Company Overview

SimoTime Technologies was founded in 1987 and is a privately owned company. We specialize in the creation and deployment of business applications using new or existing technologies and services. We have a team of individuals that understand the broad range of technologies being used in today's environments. Our customers include small businesses using Internet technologies to corporations using very large mainframe systems.

Quite often, to reach larger markets or provide a higher level of service to existing customers it requires the newer Internet technologies to work in a complementary manner with existing corporate mainframe systems. We specialize in preparing applications and the associated data that are currently residing on a single platform to be distributed across a variety of platforms.

Preparing the application programs will require the transfer of source members that will be compiled and deployed on the target platform. The data will need to be transferred between the systems and may need to be converted and validated at various stages within the process. SimoTime has the technology, services and experience to assist in the application and data management tasks involved with doing business in a multi-system environment.

Whether you want to use the Internet to expand into new market segments or as a delivery vehicle for existing business functions simply give us a call or check the web site at http://www.simotime.com


Return-to-Top
Record Concatenation, 80-byte to 1024-byte
Copyright © 1987-2024
SimoTime Technologies and Services
All Rights Reserved
When technology complements business
http://www.simotime.com