Load Halfword Functional Testing |
|
The SimoTime Home Page |
This test case includes a Job Script and High Level Assembler (HLASM) that will perform functional testing of the Load Halfword (LH) instruction. The results of the functional testing will be written to a user log file. The content of the affected General Purpose registers will be presented using hexadecimal notation.
Note: This document is being updated. If you need assistance please contact SIMOTIME Technologies.
We have made a significant effort to ensure the documents and software technologies are correct and accurate. We reserve the right to make changes without notice at any time. The function delivered in this version is based upon the enhancement requests from a specific group of users. The intent is to provide changes as the need arises and in a timeframe that is dependent upon the availability of resources.
Copyright © 1987-2024
SimoTime Technologies and Services
All Rights Reserved
This test case includes a Job Script and High Level Assembler (HLASM) that will perform functional testing of the Load Halfword (LH) instruction. The results of the functional testing will be written to a user log file. The content of the affected General Purpose registers will be presented using hexadecimal notation.
The two bytes (halfword) located at the storage address specified by operand-2 (x2+b2+d2) is treated as a 16 bit, signed binary integer and is loaded into the rightmost two bytes (bits 16-31) of the register specified by operand-1 (r1). The leftmost two bytes (bits 0-15) of the register specified by operand-1 (r1) are filled based on the sign bit from operand-2. For example, if operand-2 contains a positive value then the leftmost two bytes will be x'0000'. if operand-2 contains a negative value then the leftmost two bytes will be x'FFFF'.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
LH, Load Halfword Instruction, the operand format is R1,D2(X2,B2) |
The following shows the content of the user log file after the program is executed.
* AILH00A1 is Starting, Demo for LH Instruction... * AILH00A1 Demo for HLASM, LH Instruction v24.01.01 http://www.simotime.com * AILH00A1 Copyright 1987-2024 SimoTime Technologies All Rights Reserved * AILH00A1 Enter Task-001, Initialize Register 8 (R8) and review content ....:....1....:....2....:....3....:....4....:....5....:....6....:....7....:....8 55555555 * AILH00A1 Leave Task-001, Previous line shows content of R8 using Hex-Notation * * AILH00A1 Enter Task-002, Execute LH Instruction and Review register content * AILH00A1 Mnemonic Format . . . . LH R8,HWP_123 where HWP_123 = +123 ....:....1....:....2....:....3....:....4....:....5....:....6....:....7....:....8 0000007B * AILH00A1 Leave Task-002, Previous line shows content of R8 using Hex-Notation * * AILH00A1 Enter Task-003, Execute LH Instruction and Review register content * AILH00A1 Mnemonic Format . . . . LH R8,HWN_123 where HWN_123 = -123 ....:....1....:....2....:....3....:....4....:....5....:....6....:....7....:....8 FFFFEDCD * AILH00A1 Leave Task-003, Previous line shows content of R8 using Hex-Notation * * AILH00A1 Enter Task-004, End of Program processing * AILH00A1 is Finished, Demo for LH Instruction...
This test case will perform functional testing of the Load Halfword (LH) instruction. The results of the functional testing will be written to a user log file. The content of the affected General Purpose registers will be presented using hexadecimal notation.
This document may be used to assist as a tutorial for new programmers or as a quick reference for experienced programmers.
In the world of programming there are many ways to solve a problem. This documentation and software were developed and tested on systems that are configured for a SIMOTIME environment based on the hardware, operating systems, user requirements and security requirements. Therefore, adjustments may be needed to execute the jobs and programs when transferred to a system of a different architecture or configuration.
SIMOTIME Services has experience in moving or sharing data or application processing across a variety of systems. For additional information about SIMOTIME Services or Technologies please contact us using the information in the Contact or Feedback section of this document.
Software Agreement and Disclaimer
Permission to use, copy, modify and distribute this software, documentation or training material for any purpose requires a fee to be paid to SimoTime Technologies. Once the fee is received by SimoTime the latest version of the software, documentation or training material will be delivered and a license will be granted for use within an enterprise, provided the SimoTime copyright notice appear on all copies of the software. The SimoTime name or Logo may not be used in any advertising or publicity pertaining to the use of the software without the written permission of SimoTime Technologies.
SimoTime Technologies makes no warranty or representations about the suitability of the software, documentation or learning material for any purpose. It is provided "AS IS" without any expressed or implied warranty, including the implied warranties of merchantability, fitness for a particular purpose and non-infringement. SimoTime Technologies shall not be liable for any direct, indirect, special or consequential damages resulting from the loss of use, data or projects, whether in an action of contract or tort, arising out of or in connection with the use or performance of this software, documentation or training material.
This section includes links to documents with additional information that are beyond the scope and purpose of this document. The first group of documents may be available from a local system or via an internet connection, the second group of documents will require an internet connection.
Note: A SimoTime License is required for the items to be made available on a local system or server.
The following links may be to the current server or to the Internet.
Note: The latest versions of the SimoTime Documents and Program Suites are available on the Internet and may be accessed using the icon. If a user has a SimoTime Enterprise License the Documents and Program Suites may be available on a local server and accessed using the icon.
Explore An Enterprise System Model that describes and demonstrates how Applications that were running on a Mainframe System and non-relational data that was located on the Mainframe System were copied and deployed in a Microsoft Windows environment with Micro Focus Enterprise Server.
Explore the COBOL Connection for more examples of COBOL programming techniques and sample code.
Explore an Extended List of Software Technologies that are available for review and evaluation. The software technologies (or Z-Packs) provide individual programming examples, documentation and test data files in a single package. The Z-Packs are usually in zip format to reduce the amount of time to download.
Explore The ASCII and EBCDIC Translation Tables. These tables are provided for individuals that need to better understand the bit structures and differences of the encoding formats.
Explore The File Status Return Codes that are used to interpret the results of accessing VSAM data sets and/or QSAM files.
The following links will require an internet connection.
A good place to start is The SimoTime Home Page for access to white papers, program examples and product information. This link requires an Internet Connection
Explore The Micro Focus Web Site for more information about products (including Micro Focus COBOL) and services available from Micro Focus. This link requires an Internet Connection.
Explore the Glossary of Terms for a list of terms and definitions used in this suite of documents and white papers.
This document was created and is maintained by SimoTime Technologies. If you have any questions, suggestions, comments or feedback please use the following contact information.
1. | Send an e-mail to our helpdesk. |
1.1. | helpdesk@simotime.com. |
2. | Our telephone numbers are as follows. |
2.1. | 1 415 763-9430 office-helpdesk |
2.2. | 1 415 827-7045 mobile |
We appreciate hearing from you.
SimoTime Technologies was founded in 1987 and is a privately owned company. We specialize in the creation and deployment of business applications using new or existing technologies and services. We have a team of individuals that understand the broad range of technologies being used in today's environments. Our customers include small businesses using Internet technologies to corporations using very large mainframe systems.
Quite often, to reach larger markets or provide a higher level of service to existing customers it requires the newer Internet technologies to work in a complementary manner with existing corporate mainframe systems. We specialize in preparing applications and the associated data that are currently residing on a single platform to be distributed across a variety of platforms.
Preparing the application programs will require the transfer of source members that will be compiled and deployed on the target platform. The data will need to be transferred between the systems and may need to be converted and validated at various stages within the process. SimoTime has the technology, services and experience to assist in the application and data management tasks involved with doing business in a multi-system environment.
Whether you want to use the Internet to expand into new market segments or as a delivery vehicle for existing business functions simply give us a call or check the web site at http://www.simotime.com
Return-to-Top |
Load Halfword Instruction, Funtional Testing |
Copyright © 1987-2024 SimoTime Technologies and Services All Rights Reserved |
When technology complements business |
http://www.simotime.com |