Right Adjust and Zero-Fill
SimoRA12 - The COBOL Source Code
  Table of Contents  v-16.01.01 - simora12.htm 
  Introduction
  SimoRA12, What It Does
  SimoRA12, How To Use
  The COBOL Source Code
  The COBOL Copy File
  Summary
  Software Agreement and Disclaimer
  Downloads and Links
  Current Server or Internet Access
  Internet Access Required
  Glossary of Terms
  Comments or Feedback
  Company Overview
The SimoTime Home Page 

Table of Contents Previous Section Next Section Introduction

This document provides a listing of the COBOL source code for viewing. Additional information about this program may be obtained by sending an e-mail to: helpdesk@simotime.com

The objective of the right-adjust, zero-fill routine is to create a numeric field that will contain all digits with leading zeroes in the leftmost positions and be properly aligned to the units position. If the requirement is to right-justify, left-justify or center a text string within a field with the appropriate leading and/or trailing space characters then refer to the Text Justification document available on the SimoTime Web Site


We have made a significant effort to ensure the documents and software technologies are correct and accurate. We reserve the right to make changes without notice at any time. The function delivered in this version is based upon the enhancement requests from a specific group of users. The intent is to provide changes as the need arises and in a timeframe that is dependent upon the availability of resources.

Copyright © 1987-2024
SimoTime Technologies and Services
All Rights Reserved

Table of Contents Previous Section Next Section SimoRA12, What It Does

The SimoRA12 routine (or callable program) will right-adjust the digits and zero-fill the left-most (or high-order) bytes with leading zeroes. For example, if a value of 123 is passed to the SimoRA12 routine the following will be returned in the pass area.

********************************************************************
RIGHTADJ 123
Right Adjusted Value......... 000000000123
RC=0000, Value is Numeric

Table of Contents Previous Section Next Section SimoRA12, How To Use

The following will right-adjust the digits and zero-fill the left-most (or high-order) bytes with leading zeroes.

           MOVE 'RIGHTADJ'     to RA12-REQUEST
           MOVE '123         ' to RA12-BUFFER
           CALL 'SIMORA12'  using RA12-PASS-AREA

In the preceding example the contents of RA12-PASS-AREA will be '000000000123' upon return from the call to SIMORA12.

For a detailed description of the pass area refer to the COBOL Copy File section of this document that defines the structure of the pass area.

Table of Contents Previous Section Next Section The COBOL Source Code

The following member (SIMORA12.cbl) is the COBOL Source Code.

       IDENTIFICATION DIVISION.
       PROGRAM-ID.    SIMORA12.
       AUTHOR.        SIMOTIME TECHNOLOGIES.
      *****************************************************************
      * Copyright (C) 1987-2019 SimoTime Technologies.                *
      *                                                               *
      * All rights reserved.  Unpublished, all rights reserved under  *
      * copyright law and international treaty.  Use of a copyright   *
      * notice is precautionary only and does not imply publication   *
      * or disclosure.                                                *
      *                                                               *
      * Permission to use, copy, modify and distribute this software  *
      * for any commercial purpose requires a fee to be paid to       *
      * SimoTime Technologies. Once the fee is received by SimoTime   *
      * the latest version of the software will be delivered and a    *
      * license will be granted for use within an enterprise,         *
      * provided the SimoTime copyright notice appear on all copies   *
      * of the software. The SimoTime name or Logo may not be used    *
      * in any advertising or publicity pertaining to the use of the  *
      * software without the written permission of SimoTime           *
      * Technologies.                                                 *
      *                                                               *
      * Permission to use, copy and modify this software for any      *
      * non-commercial purpose and without fee is hereby granted,     *
      * provided the SimoTime copyright notice appear on all copies   *
      * of the software. The SimoTime name or Logo may not be used in *
      * any advertising or publicity pertaining to the use of the     *
      * software without the written permission of SimoTime           *
      * Technologies.                                                 *
      *                                                               *
      * SimoTime Technologies makes no warranty or representations    *
      * about the suitability of the software for any purpose. It is  *
      * provided "AS IS" without any expressed or implied warranty,   *
      * including the implied warranties of merchantability, fitness  *
      * for a particular purpose and non-infringement. SimoTime       *
      * Technologies shall not be liable for any direct, indirect,    *
      * special or consequential damages resulting from the loss of   *
      * use, data or projects, whether in an action of contract or    *
      * tort, arising out of or in connection with the use or         *
      * performance of this software                                  *
      *                                                               *
      * SimoTime Technologies                                         *
      * 15 Carnoustie Drive                                           *
      * Novato, CA 94949-5849                                         *
      * 415.883.6565                                                  *
      *                                                               *
      * RESTRICTED RIGHTS LEGEND                                      *
      * Use, duplication, or disclosure by the Government is subject  *
      * to restrictions as set forth in subparagraph (c)(1)(ii) of    *
      * the Rights in Technical Data and Computer Software clause at  *
      * DFARS 52.227-7013 or subparagraphs (c)(1) and (2) of          *
      * Commercial  Computer Software - Restricted Rights  at 48      *
      * CFR 52.227-19, as applicable.  Contact SimoTime Technologies, *
      * 15 Carnoustie Drive, Novato, CA 94949-5849.                   *
      *                                                               *
      *****************************************************************
      *      This program is provided by SimoTime Technologies        *
      *        Our e-mail address is: helpdesk@simotime.com           *
      *     Also, visit our Web Site at http://www.simotime.com       *
      *                                                               *
      *****************************************************************
      *
      *****************************************************************
      * Source Member: SIMORA12.CBL
      * Copy Files:    PASSRA12.CPY
      *****************************************************************
      *
      * SIMORA12 - Erase to End=Of-Field (EOF) after first space and
      * then do a Right-Adjust, Zero-Fill for a 12 byte field.
      *
      * EXECUTION or CALLING PROTOCOL
      * -----------------------------
      * CALL 'SIMORA12' USING RA12-PASS-AREA.
      *
      *****************************************************************
      *
      * MAINTENANCE
      * -----------
      * 1997/02/27 Simmons, Created program.
      * 1997/02/27 Simmons, No changes to date.
      *
      *****************************************************************
      *
       DATA DIVISION.
       WORKING-STORAGE SECTION.
       01  Z-X12                   pic 9(3)    value 0.

      *****************************************************************
       LINKAGE SECTION.
       COPY PASSRA12.

      *****************************************************************
       PROCEDURE DIVISION using RA12-PASS-AREA.
           add 16 to ZERO giving RA12-RESPOND
      *    The following INSPECT statement will erase to end-of-field
      *    any characters after the first space character.
           inspect RA12-BUFFER
                   replacing CHARACTERS by ' ' after initial ' '

      *    The following IF logic is for performance. It quickly
      *    reduces the number of loops for the PERFORM logic.
           if  RA12-BUFFER(7:6) = SPACES
               if  RA12-BUFFER(4:3) = SPACES
                   move RA12-BUFFER(1:3) to RA12-BUFFER(10:3)
                   move all ZEROES     to RA12-BUFFER(1:9)
               else
                   move RA12-BUFFER(1:6) to RA12-BUFFER(7:6)
                   move all ZEROES     to RA12-BUFFER(1:6)
               end-if
           else
               if  RA12-BUFFER(10:3) = SPACES
      *            The following three MOVE statements are used to
      *            avoid a potential problem with an overlapping MOVE.
                   move RA12-BUFFER(7:3) to RA12-BUFFER(10:3)
                   move RA12-BUFFER(4:3) to RA12-BUFFER(7:3)
                   move RA12-BUFFER(1:3) to RA12-BUFFER(4:3)
                   move all ZEROES     to RA12-BUFFER(1:3)
               end-if
           end-if

           perform until RA12-BUFFER(12:1) not = SPACE
               if  RA12-BUFFER(12:1) = SPACE
                   add 11 to ZERO giving Z-X12
                   perform 11 times
                     move RA12-BUFFER(Z-X12:1) to RA12-BUFFER
                     (Z-X12 + 1:1)
                     subtract 1 from Z-X12
                   end-perform
                   move ZERO to RA12-BUFFER(1:1)
               end-if
           end-perform

           if  RA12-BUFFER NUMERIC
               move ZERO to RA12-RESPOND
           else
               add 8 to ZERO giving RA12-RESPOND
           end-if

           GOBACK.
      *****************************************************************
      *      This example is provided by SimoTime Technologies        *
      *        Our e-mail address is: helpdesk@simotime.com           *
      *     Also, visit our Web Site at http://www.simotime.com       *
      *****************************************************************

Table of Contents Previous Section Next Section The COBOL Copy File

The following member (PASSRA12.cpy) is the COBOL copy file that may be used when calling SimoRA12.

      *****************************************************************
      *     Data Structure or Pass Area used for calling SIMORA12.    *
      *****************************************************************
      *         Copyright (C) 1987-2019 SimoTime Technologies         *
      *                     All Rights Reserved                       *
      *****************************************************************
      *              Provided by SimoTime Technologies                *
      *        Our e-mail address is: helpdesk@simotime.com           *
      *     Also, visit our Web Site at http://www.simotime.com       *
      *****************************************************************
       01  RA12-PASS-AREA.
           05  RA12-REQUEST    PIC X(8).
           05  RA12-RESPOND    PIC 9(4).
           05  RA12-BUFFER.
               10  RA12-NUMBER PIC 9(12).
      ***  PASSRA12 - End-of-Copy File - - - - - - - - - - - PASSRA12 *
      *****************************************************************
      *

Table of Contents Previous Section Next Section Summary

The objective of the right-adjust, zero-fill routine is to create a numeric field that will contain all digits with leading zeroes in the leftmost positions and be properly aligned to the units position. This document may be used to assist as a tutorial for new programmers or as a quick reference for experienced programmers.

In the world of programming there are many ways to solve a problem. This documentation and software were developed and tested on systems that are configured for a SIMOTIME environment based on the hardware, operating systems, user requirements and security requirements. Therefore, adjustments may be needed to execute the jobs and programs when transferred to a system of a different architecture or configuration.

SIMOTIME Services has experience in moving or sharing data or application processing across a variety of systems. For additional information about SIMOTIME Services or Technologies please contact us using the information in the  Contact, Comment or Feedback  section of this document.

Table of Contents Previous Section Next Section Software Agreement and Disclaimer

Permission to use, copy, modify and distribute this software, documentation or training material for any purpose requires a fee to be paid to SimoTime Technologies. Once the fee is received by SimoTime the latest version of the software, documentation or training material will be delivered and a license will be granted for use within an enterprise, provided the SimoTime copyright notice appear on all copies of the software. The SimoTime name or Logo may not be used in any advertising or publicity pertaining to the use of the software without the written permission of SimoTime Technologies.

SimoTime Technologies makes no warranty or representations about the suitability of the software, documentation or learning material for any purpose. It is provided "AS IS" without any expressed or implied warranty, including the implied warranties of merchantability, fitness for a particular purpose and non-infringement. SimoTime Technologies shall not be liable for any direct, indirect, special or consequential damages resulting from the loss of use, data or projects, whether in an action of contract or tort, arising out of or in connection with the use or performance of this software, documentation or training material.

Table of Contents Previous Section Next Section Downloads and Links

This section includes links to documents with additional information that are beyond the scope and purpose of this document. The first group of documents may be available from a local system or via an internet connection, the second group of documents will require an internet connection.

Note: A SimoTime License is required for the items to be made available on a local system or server.

Table of Contents Previous Section Next Section Current Server or Internet Access

The following links may be to the current server or to the Internet.

Note: The latest versions of the SimoTime Documents and Program Suites are available on the Internet and may be accessed using the Link to Internet icon. If a user has a SimoTime Enterprise License the Documents and Program Suites may be available on a local server and accessed using the Link to Server icon.

Link to Internet   Link to Server   Explore the COBOL Connection for more examples of COBOL programming techniques and sample code.

Link to Internet   Link to Server   Explore a complete list of the SimoTime Callable Routines or Utility Programs. This includes the callable routines and utility programs for the Micro Focus environment.

Link to Internet   Link to Server   Explore The ASCII and EBCDIC Translation Tables. These tables are provided for individuals that need to better understand the bit structures and differences of the encoding formats.

Link to Internet   Link to Server   Explore The File Status Return Codes that are used to interpret the results of accessing VSAM data sets and/or QSAM files.

Table of Contents Previous Section Next Section Internet Access Required

The following links will require an internet connect.

This suite of programs and documentation is available to download for review and evaluation purposes. Other uses will require a SimoTime Software License. Link to an Evaluation zPAK Option that includes the program members, documentation and control files.

A good place to start is The SimoTime Home Page for access to white papers, program examples and product information. This link requires an Internet Connection

Explore The Micro Focus Web Site for more information about products (including Micro Focus COBOL) and services available from Micro Focus. This link requires an Internet Connection.

Table of Contents Previous Section Next Section Glossary of Terms

Link to Internet   Link to Server   Explore the Glossary of Terms for a list of terms and definitions used in this suite of documents and white papers.

Table of Contents Previous Section Next Section Comments or Feedback

This document was created and is maintained by SimoTime Technologies. If you have any questions, suggestions, comments or feedback please use the following contact information.

1. Send an e-mail to our helpdesk.
1.1. helpdesk@simotime.com.
2. Our telephone numbers are as follows.
2.1. 1 415 763-9430 office-helpdesk
2.2. 1 415 827-7045 mobile

 

We appreciate hearing from you.

Table of Contents Previous Section Next Section Company Overview

SimoTime Technologies was founded in 1987 and is a privately owned company. We specialize in the creation and deployment of business applications using new or existing technologies and services. We have a team of individuals that understand the broad range of technologies being used in today's environments. Our customers include small businesses using Internet technologies to corporations using very large mainframe systems.

Quite often, to reach larger markets or provide a higher level of service to existing customers it requires the newer Internet technologies to work in a complementary manner with existing corporate mainframe systems. We specialize in preparing applications and the associated data that are currently residing on a single platform to be distributed across a variety of platforms.

Preparing the application programs will require the transfer of source members that will be compiled and deployed on the target platform. The data will need to be transferred between the systems and may need to be converted and validated at various stages within the process. SimoTime has the technology, services and experience to assist in the application and data management tasks involved with doing business in a multi-system environment.

Whether you want to use the Internet to expand into new market segments or as a delivery vehicle for existing business functions simply give us a call or check the web site at http://www.simotime.com


Return-to-Top
Right Adjust and Zero-Fill using COBOL
Copyright © 1987-2024
SimoTime Technologies and Services
All Rights Reserved
When technology complements business
http://www.simotime.com