SIMOHEX4 Hex-Dump of User Data String |
The SimoTime Home Page |
The SIMOHEX1 routine (or callable program) will convert a data string of one-byte items to a text string of two-byte items using hexadecimal notation. The hexadecimal notation string is then posted to the SYSOUT device. This document is a quick reference for using the callable routine SIMOHEX1. Additional information about this program may be obtained by sending an e-mail to:
Additional information about this program may be obtained by sending an e-mail to: helpdesk@simotime.com
We have made a significant effort to ensure the documents and software technologies are correct and accurate. We reserve the right to make changes without notice at any time. The function delivered in this version is based upon the enhancement requests from a specific group of users. The intent is to provide changes as the need arises and in a timeframe that is dependent upon the availability of resources.
Copyright © 1987-2024
SimoTime Technologies and Services
All Rights Reserved
The SIMOHEX1 routine (or callable program) will convert a data string to its hexadecimal value with a display or logging capability. It will also translate the possible printable characters for both ASCII and EBCDIC.
The following is an example of the hexadecimal dump information provided by the sample programs. This information may be displayed to the screen or written to a log file. The high-lighted YELLOW shows the hexadecimal dump information. The BLUE shows the possible EBCDIC display values and the RED shows the possible ASCII display values.
* CBLMEMC1 HEX-Dump of Numeric Field Formats v11.11.03 http://www.simotime.com * CBLMEMC1 Copyright 1987-2019 SimoTime Technologies All Rights Reserved * SIMOHEX1 COBOL Hexadecimal Dump Routine v16.06.15 http://www.simotime.com * SIMOHEX1 Copyright 1987-2019 SimoTime Technologies All Rights Reserved * SIMOHEX1 TXTINFO1 Text String * SIMOHEX1 ADDR is 0000000050243702 * SIMOHEX1 Starting, SIMOHEX1-ID is NBRITEMS, Dump Buffer size is 0256 Offset Hex..... ........ ........ ........ ebcdic.......... ascii........... 00000000 5049432D 39202020 30303030 30313233 &............... PIC-9 00000123 00000010 5049432D 39502020 30303030 30313233 &....&.......... PIC-9P 00000123 00000020 5049432D 394D2020 30303030 30313273 &....(.......... PIC-9M 0000012s 00000030 5049432D 395A2020 30303030 30303030 &....!.......... PIC-9Z 00000000 00000040 434F4D50 2D332020 00000000 0000123F .|(&............ COMP-3 .......? 00000050 434F4D50 2D335020 00000000 0000123C .|(&..&......... COMP-3P .......< 00000060 434F4D50 2D334D20 00000000 0000123D .|(&..(......... COMP-3M .......= 00000070 434F4D50 2D335A20 00000000 0000000C .|(&..!......... COMP-3Z ........ 00000080 434F4D50 20202020 0000007B 20202020 .|(&.......#.... COMP ...{ 00000090 434F4D50 2F502020 0000007B 20202020 .|(&.&.....#.... COMP/P ...{ 000000A0 434F4D50 2F4D2020 FFFFFF85 20202020 .|(&.(.....e.... COMP/M .... 000000B0 434F4D50 2F5A2020 00000000 20202020 .|(&.!.......... COMP/Z .... 000000C0 20202020 20202020 20202020 20202020 ................ 000000D0 20202020 20202020 20202020 20202020 ................ 000000E0 20202020 20202020 20202020 20202020 ................ 000000F0 20202020 20202020 20202020 20202020 ................ * CBLMEMC1 Thank you for using this program provided from SimoTime Technologies * CBLMEMC1 Please send all inquires or suggestions to the helpdesk@simotime.com
The coding to do the actual call to display the hexadecimal dump information to the SYSOUT device is as follows.
***************************************************************** * The coding required to do the call to the Hex-Dump program. * ------------------------------------------------------------ CALL 'SIMOHEX1' USING SIMOHEX1-PASS-AREA
SIMOHEX1-BUFFER
A copy file is provided to define the pass area to be used when calling SIMOHEX1. The following statement is required in the WORKING STORAGE section of the calling program.
WORKING STORAGE. . . . . . . COPY PASSHEX1. . . .
You may view an example of a COBOL program that uses SIMOHEX1 at http://www.simotime.com/cblmem01.htm.
The set of program members includes a program that creates the hexadecimal dump information and a copy file that defines the structure for a pass area.
The following (PASSHEX1.cpy) is the COBOL copy file that may be used when calling SIMOHEX1.
***************************************************************** * PASSHEX1 is a COBOL Copy File * * Data Structure or Pass Area used for calling SIMOHEX1. * * Copyright (C) 1987-2019 SimoTime Technologies * * All Rights Reserved * ***************************************************************** * Provided by SimoTime Technologies * * Our e-mail address is: helpdesk@simotime.com * * Also, visit our Web Site at http://www.simotime.com * ***************************************************************** * Values for SIMOHEX1-REQUEST * DUMP Dump the Buffer in Hexadecimal format * NOTE Display or Write the text to the screen or log file * * One format for calling SIMOHEX1 uses the data buffer * defined within this COBOL Copy file. * * move 'DUMP' to SIMOHEX1-REQUEST * move 'MYDUMPID' to SIMOHEX1-DUMP-ID * move SPACES to SIMOHEX1-BUFFER * move 'Text String ' to SIMOHEX1-BUFFER * add 12 to ZERO giving SIMOHEX1-LENGTH * call 'SIMOHEX1' using SIMOHEX1-PASS-AREA * SIMOHEX1-BUFFER * * An alternate call passes a user-defined data structure. * * move 'DUMP' to SIMOHEX1-REQUEST * move 'NBRITEMS' to SIMOHEX1-DUMP-ID * add length of NUMERIC-BUFFER-01 to ZERO * giving SIMOHEX1-LENGTH * call 'SIMOHEX1' using SIMOHEX1-PASS-AREA * NUMERIC-BUFFER-01 * ***************************************************************** 01 SIMOHEX1-PASS-AREA. * Initial information is provided by the calling program, * The SIMOHEX1-REQUEST field will be modified to "DUMP" if it * does not contain a valid entry. 05 SIMOHEX1-REQUEST PIC X(4). 05 SIMOHEX1-RESULT PIC 9999. 05 SIMOHEX1-DUMP-ID PIC X(8). 05 SIMOHEX1-LENGTH PIC 9(7). 01 SIMOHEX1-BUFFER PIC X(128). * *** PASSHEX1 - End-of-Copy File - - - - - - - - - - - PASSHEX1 * ***************************************************************** *
This document is a quick reference for using the callable routine SIMOHEX1. This document may be used to assist as a tutorial for new programmers or as a quick reference for experienced programmers.
In the world of programming there are many ways to solve a problem. This documentation and software were developed and tested on systems that are configured for a SIMOTIME environment based on the hardware, operating systems, user requirements and security requirements. Therefore, adjustments may be needed to execute the jobs and programs when transferred to a system of a different architecture or configuration.
SIMOTIME Services has experience in moving or sharing data or application processing across a variety of systems. For additional information about SIMOTIME Services or Technologies please contact us using the information in the Contact, Comment or Feedback section of this document.
Software Agreement and Disclaimer
Permission to use, copy, modify and distribute this software, documentation or training material for any purpose requires a fee to be paid to SimoTime Technologies. Once the fee is received by SimoTime the latest version of the software, documentation or training material will be delivered and a license will be granted for use within an enterprise, provided the SimoTime copyright notice appear on all copies of the software. The SimoTime name or Logo may not be used in any advertising or publicity pertaining to the use of the software without the written permission of SimoTime Technologies.
SimoTime Technologies makes no warranty or representations about the suitability of the software, documentation or learning material for any purpose. It is provided "AS IS" without any expressed or implied warranty, including the implied warranties of merchantability, fitness for a particular purpose and non-infringement. SimoTime Technologies shall not be liable for any direct, indirect, special or consequential damages resulting from the loss of use, data or projects, whether in an action of contract or tort, arising out of or in connection with the use or performance of this software, documentation or training material.
This section includes links to documents with additional information that are beyond the scope and purpose of this document. The first group of documents may be available from a local system or via an internet connection, the second group of documents will require an internet connection.
Note: A SimoTime License is required for the items to be made available on a local system or server.
The following links may be to the current server or to the Internet.
Note: The latest versions of the SimoTime Documents and Program Suites are available on the Internet and may be accessed using the icon. If a user has a SimoTime Enterprise License the Documents and Program Suites may be available on a local server and accessed using the icon.
Explore how to convert a memory-resident data string of one-byte items to a text string of two-byte items using hexadecimal notation. The hexadecimal notation string is then posted to the SYSOUT device. This test case executes a COBOL program that calls a COBOL program to write the HEX-Dump information to the SYSOUT device.
Explore how to convert a memory-resident data string of one-byte items to a text string of two-byte items using hexadecimal notation. The hexadecimal notation string is then posted to the SYSOUT device. This test case executes an assembler (HLASM) program that calls a COBOL program to write the HEX-Dump information to the SYSOUT device.
Explore a complete list of the SimoTime Callable Routines or Utility Programs. This includes the callable routines and utility programs for the Micro Focus environment.
Explore the COBOL Connection for more examples of COBOL programming techniques and sample code.
Explore The ASCII and EBCDIC Translation Tables. These tables are provided for individuals that need to better understand the bit structures and differences of the encoding formats.
Explore The File Status Return Codes that are used to interpret the results of accessing VSAM data sets and/or QSAM files.
The following links will require an internet connect.
This suite of programs and documentation is available to download for review and evaluation purposes. Other uses will require a SimoTime Software License. Link to an Evaluation zPAK Option that includes the program members, documentation and control files.
A good place to start is The SimoTime Home Page for access to white papers, program examples and product information. This link requires an Internet Connection
Explore The Micro Focus Web Site for more information about products (including Micro Focus COBOL) and services available from Micro Focus. This link requires an Internet Connection.
Explore the Glossary of Terms for a list of terms and definitions used in this suite of documents and white papers.
This document was created and is maintained by SimoTime Technologies. If you have any questions, suggestions, comments or feedback please use the following contact information.
1. | Send an e-mail to our helpdesk. |
1.1. | helpdesk@simotime.com. |
2. | Our telephone numbers are as follows. |
2.1. | 1 415 763-9430 office-helpdesk |
2.2. | 1 415 827-7045 mobile |
We appreciate hearing from you.
SimoTime Technologies was founded in 1987 and is a privately owned company. We specialize in the creation and deployment of business applications using new or existing technologies and services. We have a team of individuals that understand the broad range of technologies being used in today's environments. Our customers include small businesses using Internet technologies to corporations using very large mainframe systems.
Quite often, to reach larger markets or provide a higher level of service to existing customers it requires the newer Internet technologies to work in a complementary manner with existing corporate mainframe systems. We specialize in preparing applications and the associated data that are currently residing on a single platform to be distributed across a variety of platforms.
Preparing the application programs will require the transfer of source members that will be compiled and deployed on the target platform. The data will need to be transferred between the systems and may need to be converted and validated at various stages within the process. SimoTime has the technology, services and experience to assist in the application and data management tasks involved with doing business in a multi-system environment.
Whether you want to use the Internet to expand into new market segments or as a delivery vehicle for existing business functions simply give us a call or check the web site at http://www.simotime.com
Return-to-Top |
Hexadecimal Dump of a Data Buffer |
Copyright © 1987-2024 SimoTime Technologies and Services All Rights Reserved |
When technology complements business |
http://www.simotime.com |